Daikin EKHHP300AA2V3 Installation And Operating Instructions Manual page 18

Hot water heat pump indoor unit
Hide thumbs Also See for EKHHP300AA2V3:
Table of Contents

Advertisement

5
x
Start-up
1st. DAIKIN EKHHP erected in accordance with the requirements and instructions in Section 4 and shows no
damage?
2.
Minimum distance between the DAIKIN EKHHP and other sources of heat (>80 °C) of 1 m?
3.
Booster-Heater:
– Does the mains connection comply with the regulations and is the mains voltage 230 volts at 50 Hz?
– Has the residual current device been fitted in accordance with the individual country-specific regulations?
4.
Is the heat exchanger for domestic hot water heating in the DAIKIN EKHHP full and has it been bled?
4.1
Only EKHHP500AA2V3: Is the heat exchanger filled for the connection of an optional heat generator?
5.
Is the storage tank full with water to the overflow point?
6.
Is the safety overflow connection connected to an open drain?
7.
Is the water pressure on the sanitary side < 6 bar?
8.
Are all hydraulic connections tight (no leaks)?
9.
Have the parameters been set on the controller in accordance with the structural conditions, possibly connected
accessories and the user stipulations?
10.
Is the parameter [7-02] set to the value 0?
11.
Does the installation operate without faults?
12.
Has the operating manual been handed over, and has the owner been instructed?
Location and
Date:
Installation and operating instructions
18
Check list for start-up
Signature of installer:
Signature of operator:
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
DAIKIN EKHHP(3/5)00AA2V3
DAIKIN Hot water heat pump
008.1423444_05 – 08/2016

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekhhp500aa2v3