XL-1000H/1100H
IC802 VHiTC9462F/-1: Servo/Signal Control (TC9462F) (1/3)
Port Name
Input/Output
Pin No.
1*
TEST0
2*
/HSO
3*
/UHSO
4*
EMPH
5*
LRCK
6
VSS
7*
BCK
8*
AOUT
9
DOUT
10*
MBOV
11*
IPF
12*
SBOK
13*
CLCK
Input/Output
14
VDD
15
VSS
16*
DATA
17*
SFSY
18*
SBSY
19*
SPCK
20*
SPDA
21*
COFS
22*
MONIT
23
VDD
24
TESIO0
25
P2VREF
26*
HSSW
27*
ZDET
28
PDO
29*
TMAXS
30
TMAX
31
LPFN
32
LPFO
33
PVREF
34
VCOREF
35
VCOF
36
AVSS
37
SLCO
38
RFI
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Input
Test mode terminal. To be opened usually.
Output
Playback speed mode flag output terminal.
Output
/UHSO
/HSO
H
H
L
L
Output
Sub-code Q data emphasis flag output terminal. "H": Emphasis ON "L": Emphasis OFF
The output polarity can be inverted by command.
Output
Channel clock (44.1 kHz) output terminal. "L": L channel "H": R channel
The output polarity can be inverted by command.
Digital ground terminal.
Output
Bit clock (1.4122 MHz) output terminal.
Output
Audio data output terminal.
Output
Digital out output terminal.
Output
Buffer memory over signal output terminal. "H": Over
Output
Correction flag output terminal.
"H": When AOUT output is correction-disabled symbol in case of C2 correction output.
Output
Sub-code Q data CRCC judgment result output terminal. "H": When judgment result is OK.
Sub-code P-W data read clock output/input terminal. Selectable with command bit.
Input
Digital + power terminal.
Digital ground terminal.
Output
Sub-code P-W data output terminal.
Output
Playback system frame sync signal output terminal.
Output
Sub-code block sync output terminal. "H": On S1 position when the sub-code sync is detected.
Output
Processor status signal read clock (176.4 kHz) output terminal.
Output
Processor status signal output terminal.
Output
Correction system frame clock (7.35 kHz) output terminal.
Output
LSI internal signal monitor terminal.
It is possible to monitor the DSP internal flag and PLL system clock with the microcomputer
command. Terminal for serial output of text data according to command .
Input
Digital + power terminal.
Input
Test input/output terminal. To be fixed to "L" usually.
Terminal to input the text data read clock according to command.
2VREF terminal for PLL system.
Output
VREF voltage in case of x2 speed/x4 speed.
Output
1-bit DAC zero detection flag output terminal.
Output
Terminal to output the phase difference between EFM signal and PLCK signal.
Output
TMAX detection result output terminal. To be selected with command bit TMPS.
Output
TMAX detection result output terminal. To be selected with command bit TMPS.
TMAX detection result
Longer than specific period
Shorter than specific period
Within specific period
Input
Low-pass filter amp inverted input terminal.
Output
Low-pass filter amp output terminal.
Input
VREF terminal for PLL system.
Input
VCO center frequency standard level terminal. To be fixed to PVref usually.
Output
VCO filter terminal.
Analog system ground terminal.
Output
Data slice level generation DAC output terminal.
Input
RF signal input terminal.
Function
Playback speed
H
x1 speed playback
L
x2 speed playback
H
x4 speed playback
L
TMAX output
"P2VREF"
"VSS"
"HIZ"
– 56 –