Page 1
Gelovit 200 English Translation of the original instructions...
Page 2
This symbol indicates very important information. Failure to comply with it may result in personal injury. This symbol warns you of hot parts. BEGO Bremer Goldschlägerei Wilh. Herbst GmbH & Co • Wilhelm Herbst-Straße 1 • D-28359 Bremen Telefon +49 421 2028-0 • Telefax +49 421 2028-100 • www.bego.com...
Gelovit 200 Contents Page Operating Instructions Safety instructions --------------------------------------------------------------------------- 4 About the unit Unit description ------------------------------------------------------- 6 Scope of delivery and special accessories ------------------------ 8 Technical data --------------------------------------------------------- 8 Operation Installation ------------------------------------------------------------- 8 Check set temperatures ---------------------------------------------- 9 Filling ------------------------------------------------------------------- 9...
• The l Repairs unit must only be used in dry rooms. Repairs may be carried out solely by BEGO customer service or by persons authorised by l Operator and operating personnel BEGO customer service. • Metallic housings...
Page 5
Gelovit 200 Special safety instructions concerning this unit Risk of injury! l During the melting process the housing and cover become hot! Let the unit cool down or use safety gloves before touching the cover. l Be careful when reaching into the container.
Page 7
Gelovit 200 is used to melt and store gel duplicating Built-in timer material. The temperature of the duplicating material By means of a timer, the unit can be set for the night can be constantly read off an electronic display.
Check/change T2 and T3 in the same way. Notes: ® • The factory-set temperatures are recommended for BEGO duplicating materials Castogel ® Wirodouble T1 melting temperature = 93 °C, T2 operating temperature = 42 °C, (T2 cannot be set lower than T3.)
Gelovit 200 Switching on and duplicating 1 Switch on main power switch on right side of unit. 2 Display shows actual temperature of the duplicat- ing material. 3 Press T1 (see notes). After the desired temperature is reached: 2 2,5 4 Place flask under the outlet.
Gelovit 200 Timer The timer means the unit can be set to switch on at a desired time. The duplicating material can be 6 2 0 0 removed after 3-4 hours, depending on the duplicating material used and the manufacturer.
Gelovit 200 Care and maintenance l Let duplicating material that has overflowed harden and then collect it. Fill in with new dupli- cating material at next melting operation. l Clean housing with water and mild cleaning agent. - Do not use cleaning agents in the duplicating material container.