Magnavox 19MDTR20 Service Manual page 340

With built-in vcr/dvd player
Hide thumbs Also See for 19MDTR20:
Table of Contents

Advertisement

Main CBA Top View < TV/VCR Section >
Because a hot chassis ground is present in the power
supply circuit, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly,when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
CAUTION ! :
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
4A 125V
ATTENTION : Utiliser un fusible de rechange de même type de 4A, 125V.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
TO SENSOR CBA
Otherwise it may cause some components in the power supply circuit to fail.
(END-SENSOR)
1-11-15
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
TP1673
TP1672
DVD-Y
TP1301
VR1601
D1613 Cathode
(+B Adjustment)
PIN 58
OF IC1201
PIN 59
OF IC1201
TP1401
TO SENSOR CBA
(START-SENSOR)
Sensor CBA Top View
BHF300F01011A
BHF300F01011B
WF18
DVD-C
WF17
B-OUT
+B ADJ
WF15
WF16
WF5
V-OUT
BT2100F01012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

19mdtr1727mdtr20s27mdtr17s

Table of Contents