Electrical Wiring Diagrams - Mitsubishi Electric PLFY-P-NCMU-E Data Book

Air conditioning systems
Hide thumbs Also See for PLFY-P-NCMU-E:
Table of Contents

Advertisement

4. ELECTRICAL WIRING DIAGRAMS

PLFY-EP08, 12, 15, 18, 24, 30, 36, 48NEMU-E
* Be sure to turn off the source power and then
disconnect fan motor connector.
(Failure to do so will cause trouble in Fan motor)
MF
MS
3~
I.B
1
CNMF
(WH)
+
POWER SUPPLY
208/230V AC 60Hz
BREAKER
(16A)
1
3
5
FUSE(16A)
* 1
BK
RD
PULL BOX
L1
BU
L2
TO NEXT
INDOOR UNIT
<Table 1> SW2 (CAPACITY CODE)
MODELS
SW2
MODELS
SW2
ON
ON
08
24
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
12
30
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
15
36
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
18
48
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
SYMBOL
NAME
I. B
INDOOR CONTROLLER BOARD
F1
FUSE (UL 6.3A 250V AC)
CN24
CONNECTOR
EXTERNAL HEATER
CN27
DAMPER
CN32
REMOTE SWITCH
CN51
CENTRALLY CONTROL
CN52
REMOTE INDICATION
MODE SELECTION
SW1
SWITCH
SW2
CAPACITY CODE
MODE SELECTION
SW3
SW4
MODEL SELECTION
SW11
ADDRESS SETTING 1s DIGIT
SW12
ADDRESS SETTING 10s DIGIT
SW14
BRANCH NO.
SW21
CEILNG HEIGHT/DISCHARGE OUTLET
NUMBER/OPTION SELECTOR
SW22
PAIR NO. SETTING
SWE
DRAIN PUMP (TEST MODE)
THERMISTOR
ROOM TEMP. DETECTION
TH21
(32ºF/15kΩ, 77ºF/5.4kΩ)
LED on indoor board for service
Mark
Meaning
Main Power supply (Indoor unit:208/230V AC)
LED1
Main power supply
power on → lamp is lit
Power supply for
Power supply for MA-Remote controller
LED2
MA-Remote controller
on → lamp is lit
MEE16K008_U
W.B
BZ
CNB
LED2 LED1
RU
9
1
SW1
SW2
DP
MS
3~
9
7
4
1
3
CNP
(WH)
9
1
2
CN90
CN27
(WH)
(RD)
LED1
SWE
-
F1
O
F F
O
N
CN4Z
(WH)
4
0 9 8 7 6 5 4 3 2 1
CND
OFF
(BK)
ON
1
SW3
SW4
I-SEE SENSOR
Refer to table 2.
(CORNER PANEL
OPTION PART)
I-SEE
SENSOR
<Table 2> SW4 (MODEL SELECTION)
MODELS
SW equipped
PLFY-EP.
ON
OFF
NEMU-E
1 2 3 4 5 6
SYMBOL
TH22
THERMISTOR
TH23
MF
FAN MOTOR
MV
VANE MOTOR
MT
I-SEE SENSOR MOTOR
DP
DRAIN PUMP
FS
DRAIN FLOAT SWITCH
TB2
TERMINAL
TB5
BLOCK
TB15
LEV
LINEAR EXPANSION VALVE
OPTION PART
PCB FOR WIRELESS REMOTE CONTROLLER
W.B
BZ
BUZZER
LED1
LED (OPERATION INDICATION : GREEN)
LED2
LED (PREPARATION FOR HEATING : ORANGE)
RU
RECEVING UNIT
SW1
EMERGENCY OPERATION (HEAT / DOWN)
SW2
EMERGENCY OPERATION (COOL / UP)
Function
TH22
FS
TH21
TH23
1
1
4
2
1
5
4
CN4F
CN44
CN51
CN20
(WH)
(WH)
(WH)
(RD)
1
2
1
CN5Y
CN60
CN24
(WH)
(WH)
(YE)
5
1
6
3
CN32
(WH)
SW11
6 5 4 3 2 1
0 9 8 7 6 5 4 3 2 1
4 3 2 1
OFF
OFF
OFF
ON
ON
ON
SW2
SW1
SW22
1s DIGIT
Refer to table 1.
M
MT
NOTES:
1. At servicing for outdoor unit, always follow the wiring diagram of outdoor unit.
2. In case of using MA-Remote controller, please connect to TB15. (Remote controller wire is non-polar.)
3. In case of using M-NET-Remote controller, please connect to TB5. (Transmission line is non-polar.)
4. Symbol [S]of TB5 is the shield wire connection.
5. Symbols used in wiring diagram above are,
6. The setting of SW2 and SW4 differs in the capacity and model. For the detail, refer the table 1 and 2.
7. Make sure to turn off the indoor and the outdoor units before replacing indoor controller board.
8.
is the switch position.
*1. Use copper supply wires.
*1. Utilisez des fils d'alimentation en cuivre.
NAME
PIPE TEMP. DETECTION / LIQUID
(32ºF/15kΩ, 77ºF/5.4kΩ)
PIPE TEMP. DETECTION / GAS
(32ºF/15kΩ, 77ºF/5.4kΩ)
POWER SUPPLY
TRANSMISSION
MA-REMOTE CONTROLLER
LEV
M
6
1
5
1
TB15
2
CN52
1
(GN)
TB5
LED2
S
M2
1
M1
2
1
1
CNV
(WH)
SW12
SW14
6 5 4 3 2 1
OFF
ON
19
20
BRANCH No.
10s DIGIT
SW21
20
5
5
5
M
M
M
V
M
V
: terminal block,
: connector.
TO MA-REMOTE
CONTROLLER
8.7-13V DC
TO OUTDOOR UNIT
BC CONTROLLER
REMOTE CONTROLLER
24-30V DC