QARDIO
QardioArm A100
A Smarter Read on Blood Pressure
User Guide
Draft 0.9 – drawings to be replaced.
not paginated and not formatted.

Advertisement

loading
Need help?

Need help?

Do you have a question about the QardioArm A100 and is the answer not in the manual?

Questions and answers

Khalid Ashour
May 15, 2025

Is it rechargeable batteries

1 comments:
Mr. Anderson
May 22, 2025

No, the Qardio A100 uses four AAA alkaline batteries, which are not rechargeable.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Qardio QardioArm A100

  • Page 1 QARDIO QardioArm A100 A Smarter Read on Blood Pressure User Guide Draft 0.9 – drawings to be replaced. not paginated and not formatted.
  • Page 2 This device was developed in collaboration with physicians and clinical tests were carried out prove its measurement accuracy. Every day, we at Qardio put our passion and effort into bringing you products of superior quality, design and technology that can change your life for the better.
  • Page 3 4. Fit the Qardio Arm on the upper arm 5. With the Qardio app open, touch your device on the QardioArm to perform the pairing of your QardioArm with your phone or tablet. You should accept the pairing request. 6. On the Qardio app, press the green START button to initiate the blood pressure measurment.
  • Page 4  Make sure that the cuff is positioned 2cm (0.8in) above the elbow. The QardioArm must be positioned over the artery that runs down the inner side of the arm. The Qardio logo should be on bottom, towards your hand.
  • Page 5 There is a break of 30 seconds between the measurements. A count down indicates the remaining time.The individual results are not displayed. Your blood pressure will only be displayed after all measurements are taken. Do not remove the cuff between measurements.
  • Page 6 Although the QardioArm will continue to measure reliably, you should obtain replacement batteries. If the empty battery symbol appears on the Qardio app, your QardioArm batteries are depleted and it’s time to replace them. You cannot take any further measurements and must replace the batteries. You should replace all four AAA alkaline batteries at the same time.
  • Page 7 Caution Self-diagnosis of measurement results and self-treatment are potentially dangerous. You should always consult your doctor. People with severe blood flow problems, or blood disorders, should consult a doctor before using the blood pressure monitor as cuff inflation might cause internal bleeding. Complicating factors such as common arrhythmias, ventricular premature beats, atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, age, pregnancy, preeclampsia or renal disease can affect the performance of the automated sphygmomanometer and/or its blood pressure reading.
  • Page 8 Qardio App to verify you are positioning the QardioArm correctly. If the problem occurs again, please contact customer service.
  • Page 9 (measured by close fitting in the centre of the upper arm). Customer service contact Qardio customer service is available on www.getqardio.com. Guarantee This device is covered by a three-year guarantee from the date of purchase. The guarantee is valid only on presentation of the purchase receipt confirming date of purchase.
  • Page 10 Measurement: Oscillometric method with automatic inflation and controlled pressure release valve. Measurement range: 40~250 mmHg for blood pressure, 40~200 beats/minute for pulse. Technical measuring precision: Cuff pressure Accuracy: ±3mmHg or ±2% of readout value for blood pressure. ±5% of readout for pulse. Measurement resolution: 1mmHg for blood pressure.
  • Page 11 IEC/EN 60601-1-11 : General requirements for basic safety and essential performance –Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment IEC 80601-2-30: 2009 (First Edition) for use in conjunction with IEC 60601-1:2005 EN 80601-2-30: 2010/ ANSI/AAMI 80601-2-30: 2009 : Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers EN300328 V1.7.1 :2006 Electromagnetic compatibility and Radio spectrum Matters (ERM);...
  • Page 12 FCC/IC Caution: 1. This device complies with Part 15 of the FCC rules/ Industry Canada licence‐exempt RSS standard(s). Operation is subject to the following two conditions : 1) this device may not cause harmful interference and 2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 13 equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. En vertu de la réglementation de l'industrie du Canada, cet émetteur de radio ne peuvent fonctionner en utilisant une antenne d'un type et maximum (ou moins) Gain approuvé pour l'émetteur par Industrie Canada.
  • Page 14 Harmonic emissions The BP-801 Wireless Blood Pressure Monitor is Not applicable IEC 61000-3-2 suitable for use in all establishments, including domestic establishments and those directly Voltage fluctuations/ connected to the public low-voltage power supply Flicker emissions Not applicable network that supplies buildings used for domestic IEC 61000-3-3 purposes.
  • Page 15 Apple Inc., registered in the U.S. and other countries. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Qardio, Inc. is under license. Other trademarks and trade names are those of their respective owners.