Electrical; About The Documentation; About This Document; Installer Reference Guide At A Glance - Daikin EBLQ05+07CAV3 Installer's Reference Manual

Altherma low temperature monobloc
Table of Contents

Advertisement

2 About the documentation

1.2.6

Electrical

DANGER: RISK OF ELECTROCUTION
▪ Turn OFF all power supply before removing the
switch  box cover, connecting electrical wiring or
touching electrical parts.
▪ Disconnect the power supply for more than 1  minute,
and measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing.
The voltage MUST be less than 50  V  DC before you
can touch electrical components. For the location of the
terminals, see the wiring diagram.
▪ Do NOT touch electrical components with wet hands.
▪ Do NOT leave the unit unattended when the service
cover is removed.
WARNING
If NOT factory installed, a main switch or other means for
disconnection, having a contact separation in all poles
providing full disconnection under overvoltage category  III
condition, shall be installed in the fixed wiring.
WARNING
▪ ONLY use copper wires.
▪ Make sure the field wiring complies with the applicable
legislation.
▪ All field wiring must be performed in accordance with
the wiring diagram supplied with the product.
▪ NEVER squeeze bundled cables and make sure they
do not come in contact with the piping and sharp
edges. Make sure no external pressure is applied to the
terminal connections.
▪ Make sure to install earth wiring. Do NOT earth the unit
to a utility pipe, surge absorber, or telephone earth.
Incomplete earth may cause electrical shock.
▪ Make sure to use a dedicated power circuit. NEVER
use a power supply shared by another appliance.
▪ Make sure to install the required fuses or circuit
breakers.
▪ Make sure to install an earth leakage protector. Failure
to do so may cause electric shock or fire.
▪ When installing the earth leakage protector, make sure
it is compatible with the inverter (resistant to high
frequency electric noise) to avoid unnecessary opening
of the earth leakage protector.
Install power cables at least 1 metre away from televisions or radios
to prevent interference. Depending on the radio waves, a distance of
1 metre may not be sufficient.
WARNING
▪ After finishing the electrical work, confirm that each
electrical component and terminal inside the electrical
components box is connected securely.
▪ Make sure all covers are closed before starting up the
unit.
NOTICE
Only applicable if the power supply is three‑phase, and the
compressor has an ON/OFF starting method.
If there exists the possibility of reversed phase after a
momentary black out and the power goes on and off while
the product is operating, attach a reversed phase
protection circuit locally. Running the product in reversed
phase can break the compressor and other parts.
Installer reference guide
6
2
About the documentation
2.1

About this document

Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
Document
Contains...
General
Safety instructions that
safety
you must read before
precautions
installing
Outdoor unit
Installation instructions
installation
manual
Control box
Installation instructions
installation
manual
Option box
Installation instructions
installation
manual
Backup
Installation instructions
heater
installation
manual
Installer
Preparation of the
reference
installation, technical
guide
specifications, good
practices, reference data,
...
Addendum
Additional info about how
book for
to install optional
optional
equipment
equipment
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
2.2
Installer reference guide at a
glance
Chapter
General safety
Safety instructions that you must read
precautions
before installing
About the documentation
What documentation exists for the
installer
About the box
How to unpack the units and remove
their accessories
About the units and
▪ How to identify the units
options
▪ Possible combinations of units and
options
Application guidelines
Various installation setups of the system
Preparation
What to do and know before going
on‑site
Installation
What to do and know to install the
system
EBLQ05+07CAV3 + EDLQ05+07CAV3 + EKCB07CAV3 +
EK2CB07CAV3 + EKMBUHCA3V3 + EKMBUHCA9W1
Daikin Altherma low temperature monobloc
Format
Paper (in the box of the
outdoor unit)
Paper (in the box of the
outdoor unit)
Paper (in the box of the
control box)
Paper (in the box of the
option box)
Paper (in the box of the
backup heater)
Digital files on
http://
www.daikineurope.com/
support-and-manuals/
product-information/.
Paper (in the box of the
outdoor unit)
Digital files on
http://
www.daikineurope.com/
support-and-manuals/
product-information/.
Description
4P405544-1 – 2015.03

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents