7. PROFIdrive acyclic parameter access

In this product, inverter parameters and PROFIdrive parameters are accessible by acyclic
communications in addition to the cyclic communication via Telegram 100 or101.
When you use acyclic parameter access, the value is written to the EEPROM.

7.1. Example1. Read the PROFIdrive parameter

7.1.1.
Request Format (Read the value of PNU 964 (0x03C4) IND 0)
Field
Request Header (Byte 1)
Request Header (Byte 2)
Request Header (Byte 3)
Request Header (Byte 4)
Parameter Address (Byte 1)
Parameter Address (Byte 2)
Parameter Address (Byte 3)
Parameter Address (Byte 4)
Parameter Address (Byte 5)
Parameter Address (Byte 6)
7.1.2.
Response format
Field
Request Header (Byte 1)
Request Header (Byte 2)
Request Header (Byte 3)
Request Header (Byte 4)
Parameter Value (Byte 1)
Parameter Value (Byte 2)
Parameter Value (Byte 3)
Parameter Value (Byte 4)
Notes
Description
Request Reference
Request ID (0x01: Request)
Axis
Number of Parameters
Attribute (0x10: Value)
Number of Elements
Parameter number (PNU), High byte
Parameter number (PNU), Low byte
Sub index (IND), High byte
Sub index (IND), Low byte
Description
Request Reference (mirrored)
Response ID
Axis (mirrored)
Number of Parameters
Format
Number of Values
Values, High byte
Values, Low byte
- 55 -
E6582051
Value
0x01
0x01
0x01
0x01
0x10
0x01
0x03
0xC4
0x00
0x00
Value
0x01
0x01
0x01
0x01
0x06
0x01
0x01
0x90