Toshiba TOSVERT VF-S15 Manual page 47

Hide thumbs Also See for TOSVERT VF-S15:
Table of Contents

Advertisement

fd01 (Inverter operating status 1 (real time)) (VF-AS3)
6.5.13.
bit
Function
0
Failure FL
1
Failure
2
Alarm
3
Under voltage (moff) Normal
4
V/f switching status
5
PID control off
6
Acc/Dec switching status AD mode 1
7
DC braking
8
Jog run
9
Forward / reverse run
10
Run/stop
11
Coast stop (ST = OFF)
12
Emergency stop
13
Standby ST=ON
14
Standby
HAND/AUTO
15
(LOC/REM)
0
1
No output
Under in progress -
Not tripped
Tripped
No alarm
Alarm issued
Under voltage
V/f 1
V/f 2
PID control
PID control
permitted
prohibits
AD mode 2
Forced DC
OFF
braking
OFF
Jog run
Forward run
Reverse run
Stop
Run
ST=ON
ST=OFF
No emergency
Emergency
stop status
stop status
Start-up process Standby
Start-up process Standby
AUTO
HAND
(REM)
(LOC)
- 44 -
E6582051
Note
Trip status includes rtry and
the trip retention status are also
regarded as tripped statuses.
-
-
1: pt = setting value, vl,
V/f
vlv, vb, thra
2: pt = 0, f170, f171,
V/f
f172, f182
-
AD mode 1: acc, dec
AD mode 2: f500, f501
-
-
-
-
-
-
Standby: Initialization
completed, not failure stop
status, not alarm stop status
(moff, ll forced stop),
ST=ON, and RUN=ON
Standby: Initialization completed,
not failure stop status and not
alarm stop status (moff, ll
forced stop)
Enabled with f750="2"
HAND: Panel operation is enabled
AUTO: Operation method selected
cmod and fmod are enabled.
Enabled with f732="0"
LOC: Panel operation is enabled
REM: Operation method selected
cmod and fmod are enabled.