Silometer FMX 570
Construction
Electrical connection
Outputs
Certificates
14
2.5

Technical data: Silometer FMX 570 transmitter

Fig. 2.8
Silometer FMX 570 plug-in card
• Design:
• Front panel:
• Dimensions:
• Weight:
• Operating temperature:
Storage temperature:
• Multipoint plug:
• Power supply:
• Supply current:
• Signal inputs:
• Probes:
• Electromagnetic
compatibility:
• Analogue output:
• Alarm relay
• Silometer FMX 570
19", 7 HP, plug-in card
black synthetic with blue field inlay, grip and markings,
Protection: IP 20 (DIN 40050)
see diagram
approx. 0.3 kg/11 oz
-0 °C...+70 °C/+32 °F..158 °F
-20 °C...+85 °C/-4 °F...185 °F
conforming to DIN 41612, Part 3, Type F (28-pole)
Coding pins in positions 2 and 9
24 V DC (+6 V...-4 V); residual ripple 2 V, within tolerance
approx. 90 mA, max. 125 mA
Electrically isolated from the rest of the circuitry.
Protection [EEx ia] IIC or IIB
Capitance probes, impedance probes
with EC 37 Z or EC 47 Z electronic insert
Deltapilot S with electronic insert FEB 17 / FEB 17 P
Interference Emission to EN 61326, Electrical Equipment Class A
Interference Immunity to EN 61326
0...20 mA/4...20 mA selectable, R
0...10 V/2...10 V selectable, R
relay with a potential-free change-over contact
Max. switching capacity:
2.5 A, 250 VAC, 300 VA at cos ϕ > 0.7 or
100 VDC, 90 W
Intrinsically safe circuit to [EEx ia] IIC and IIB
(PTB certification in preparation)
see also »Safety Notes«.
Chapter 2: Installation
BA119E22
max. 500 Ω
L
min. 10 k Ω
L