DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- Disassembly Heater assy.
Remove the base by unscrewing the 8 Torx screws.
Disconnect the wires that are connected to the heater assy.
Remove the switch assy by removing the 3 Nuts.
Remove the Cir clip that fi xes the heater assy.
Open the lid and gently push (force maybe needed) on the
inside of the heater.
The heater and Gasket will move out of the Kettle body.
Remove the Gasket from the heater.
- Re-assembly the heater assy.
Place the gasket on the heater assy. (see picture for
placement details.)
Make the outside of the gasket and the inside of the Kettle
housing were the gasket will be placed wet with plain water.
Gently push the heater assy with gasket equable in the
Kettle body. While pushing inwards check if the gasket
keeps well around the heater assy.
The heater assy and gasket has to be pushed over the ridge.
Check visual if the gasket is correct placed.
Reassembly the Cir clip for fi xation of the heater assy.
By fi lling the kettle with plain water and leave it for half an
hour, you can check if the gasket properly sealed the Kettle.
- Reassemble the switch assy.
Connect the wires again.
Fix the base again.
Check the functions of the Kettle.
PARTS LIST
Pos
Service code
1
9965 000 32729
2
9965 000 32730
3
9965 000 32728
4
9965 000 32731
5
9965 000 32727
6
9965 000 32725
7
9965 000 32724
8
9965 000 32726
9
9965 000 32723
10
9965 000 32732
11
9965 000 32715
12
9965 000 32716
= changed
Description
Alu lid wrap
Lid opening switch
Lid cover
Lid locker
Lid seal ring
Alu body wrap
Filter
Wire fi lter
Lower fi lter
Damper assy complete
Handle cover
Handle
REPAIR INSTRUCTION
- Electrical circuit
When the appliance does not work, check the electrical
Circuit.
- De-scaling
Fill the kettle with water up to three-quarters of the
maximum level indication and press the on/off switch.
After the kettle has switched itself off, add white vinegar
(8% acetic acid) or an appropriate descaler up to the
maximum level indication.
Leave the solution in the kettle overnight.
Empty the kettle and rinse the inside thoroughly.
Repeat this procedure if there is still some scale left in the
kettle.
- Cleaning filter
Clean the fi lter by rinsing it under a running tap.
If necessary, you can use a soft nylon brush.
The scale fi lter can also be cleaned in the dishwasher or
clean the fi lter by de-scaling it in the same way as the kettle.
Let the fi lter soak in a cup of warm water with some white
vinegar or an appropriate descaler.
Take the fi lter out of the cup and rinse it thoroughly.
OPTIONAL (accessories)
- No specific issues.
Pos
Service code
13
9965 000 32722
14
9965 000 32721
15
9965 000 32717
16
9965 000 32714
17
9965 000 32713
18*
9965 000 32720
19
9965 000 32712
20*
9965 000 32719
21
9965 000 32718
22
9965 000 32709
23
9965 000 32710
24
9965 000 32711
* Not available for appliances produced after week 832
HD4690
Description
Seal ring
Heater
Switch toggle
Switch ring
Switch lever Alu
Circlep
Lower steam guide
Switch assy
Kettle base
Plug CS7
Base Cover
Rubber feet
2-4

Advertisement

loading