AC power
The unit is supplied with a power plug appropriate to its voltage. Should any other connections be required they must be carried
out with the following configuration:
Cable (EU)
Brown
Light blue
Yellow/green
DMX-512 connection
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first
unit in a DMX chain. If you wish to connect a DMX controller with other XLR outputs you will need to use adapter cables.
DMX output
Connect the DMX output of the first unit in a DMX chain with the DMX input of the next unit in the chain. Always connect the the
output of one unit with the input of the next unit until all units are connected.
Rear panel features
Number
Feature
1
Power supply input
2
Mic
3
Display/Function buttons
4
DMX output
5
DMX input
Function setting
Using the four function buttons on the rear of the unit you can set the operating mode of the unit. Press the Menu button to
display the different functions (see table below for a description of the functions). Use the Up or Down arrow buttons to make
your selection. When you have chosen your desired function, press the Enter button to confirm the change.
Cable (US)
Black
White
Neutral
Green
1 = Shield
2 = Signal (-)
3 = Signal (+)
Function
Attach the mains cable here. Built-in fuse.
Microphone for Sound-to-Light operation.
LED display and menu buttons to control the operating mode of the unit.
3 pin XLR connector for DMX512 output communication.
3 pin XLR connector for DMX512 input communication.
Pin
International
Live
L
N
Earth
DMX input