LEMO CONNECTOR SIGNAL INFORMATION

POWER CONNECTOR
Voltage Limit
Characteristics
Maximum input voltage
Minimum input voltage
CURRENT LIMIT
The Power + signal will conform to the following current requirements:
Characteristics
Typically average current consumption for Power +
Typically peak current consumption for Power +
Typically peak power consumption for Power +
It is recommended to use a Class II double insulated power supply, or a power limited external
battery. The source should always be limited to a output power of no more than 100 watts in
total.
CONNECT OR PIN NVO.
Signal Name
Power cable wire colour
1 GND
2 VCC
MALE PLUG PIN-OUT
The below illustration shows the connectors pin-out seen from the solder
side of the male plug.
1
2
Power Connector
Symbol
Value
Unit (DC)
VSOH
24
V
VSOH
12
V
Symbol
Value
Unit (DC)
ICCA
1000
mA
ICCP
2500
mA
ICCP
25
Watt
Signal description
White
Power GND (-)
Brown
Main power (+)
= Index Marker
1
8
2
9
7
3
10
6
4
5
Control Connector A & B
CONTROL CONNECTOR A & B
The below table shows the connectors pin numbers, signal names and signal
direction in the control connector.
Connect
Control
Signal name
Signal description
or pin no.
cable
1
White
CL
Reserved for future use
2
Brown
CH
Reserved for future use
3
Green
Vsys -
0 VDC Logic Supply
4
Yellow
Vsys +
+ 5 VDC Logic Supply
5
Grey
RX
Serial channel, RX signal
6
Pink
TRIG
Trig Camera
7
Blue
- BUSY
Camera Busy
8
Red
INTERNAL
Reserved
9
Black
- EXPOSE
Shutter Open
10
Purple
TX
Serial channel, TX signal
Shield
GROUND
GROUND
Chassis ground
SYSTEM LOGIC SUPPLY SIGNALS
The VSYS+ power is always supplied to the control connector from the
Camera housing.
SYSTEM STARTUP
During system startup (when the main power is applied into the Camera
housing) the following requirements will apply for the System Logic supply
signal +VSYS:
Characteristics
Maximum +VSYS voltage rise time
The total capacitive load between +VSYS and -VSYS should not exceed the
following limit:
Characteristics
Maximum capacitive load on VSYS
A6D User Manual
Direction
Type
InOut
I/O
InOut
I/O
-
POWER
-
POWER
Input
CMOS
Input
CMOS
Output
OC
InOut
-
Output
OC
Output
CMOS
Camera↔External flash
-
Symbol
Value
Unit (AC)
TRVS
40
ms
Symbol
Value
Unit
CLVS
150
µf
18