2-3-4. Communication Monitoring Display
The communication state is monitored and displayed while the
key name on the main unit and the remote commander is displayed.
When the communication to the System Controller failed, DVD
and VCD segments turn on.
Communication error display (at no input of key and remote com-
mander)
Communication error display (at code display without input of
the remote commander)
2-3-5. FLD Anode Test Display and SHUTTLE Click
Operation Test
2-3-5-1. Transition Keys in Self Check Mode
Key on the remote commander
• SHUTTLE on the remote commander during Anode Test dis-
play
2-3-5-2. Operation and Display
The Self Check Mode transits to this mode when
key is en-
tered. This tests whether each segment turns on individually. Only
the first segment of each grid of FLD turns on, and each time the
SHUTTLE is entered, the segment of each grid is switched in or-
der. When SHUTTLE input is clockwise, the segment switches in
1 → 2 → 3 direction, or counterclockwise it switches in 3 → 2 →
1 direction.
Display at the start of Anode Test
(Input in CW direction)