EEPROM Data 3
CD LCD
Analog FRSW
xx xx
PLL Dac Gain xx xx
Mirror Time
xx xx
THR A&L:
xx xx xx/xx xx xx
_ UP
: PREV Data
DOWN : First Data
CLEAR : Default Set
On this screen, current servo adjusted data stored in the EEPROM
are displayed. The adjusted data are initialized by pressing the
[CLEAR]
key, but be careful that they are not recoverable after
initialization.
Before clearing the adjusted data, make a note of the set data. This
[0]
screen will also appear if
Adjustment. In this case, default setting cannot be made.
Data of "THR A & L" on page 3/3 can not be changed if default
set is done.

6-6. MECHA AGING

### Mecha Aging ###
Press OPEN key
_
Abort: STOP key
On the Test Mode Menu screen, selecting
of mechanism. First, open the tray and load a disc. Press
the
H
key, and the aging will start. During aging, the repeat cycle
is displayed. Aging can be aborted at any time by pressing
the
key. After the operation has stopped, unload the disc and
x
press again the
x
key or the
Test Mode Menu.
-– DL -–
SL L0 L1
xx xx xx
xx xx xx
xx xx xx
page.3/3
All is selected in the Drive Auto
[3]
executes the aging
[
RETURN]
O
key to return to the

6-7. EMERGENCY HISTORY

### EMG. History ###
Laser Hours
CD
DVD
1. 00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
_
Select: 1-9
Scroll :UP/DOWN
(1: Last EMG.)
On the Test Mode Menu screen, selecting
mation such as servo emergency history. The history information
from last 1 up to 10 can be scrolled with ↑ key or ↓ key. Also,
specific information can be displayed by directly entering that
number with ten keys.
The upper two lines display the laser ON total hours. Data below
minutes are omitted.
Clearing History Information
Clearing laser hours
[DISPLAY]
Press
and
Both CD and DVD data are cleared.
Clearing emergency history
[TOP MENU]
Press
Initializing set up data
[MENU]
Press
and
The data have been initialized when "Set Up Initialized" mes-
sage is displayed. The EMG. History screen will be restored
soon.
6-11
xxh xxm
xxh xxm
00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
Exit :RETURN
[4]
displays the infor-
[CLEAR]
keys in this order.
[CLEAR]
and
keys in this order.
[CLEAR]
keys in this order.