Heat And Cool - Radio Thermostat CT101 Install Manual

Hide thumbs Also See for CT101:
Table of Contents

Advertisement

HVAC Setup on Screen
IMPORTANT: Make sure the CT101 is powered up and
the mode is set to OFF. HVAC selection switches must be
set first [pg 8].
• With mode in OFF press MENU and touch HVAC SET UP.
• Use +/- icons to select HVAC SET UP number on screen.
The LCD display will show your selection and indicate the
number of stages you have selected. During setup, 2nd
stage will blink when both heat and cool have 2nd stages.
If you have a Normal HVAC system and
you want fast temperature recovery...

HEAT and COOL

2 stage HEAT, 1 stage COOL select
1 stage HEAT, 2 stage COOL select
2 stage HEAT, 2 stage COOL select
Caution
thermostat is included to Z-Wave network. The HVAC system must be changed, first EXCLUDE the
thermostat from the network, change the HVAC setup, and INCLUDE the thermostat to the network.
If you have a HEAT PUMP HVAC system...
HEAT PUMP with no AUX heat
1
2stage HEAT PUMP with no AUX
select
HEAT PUMP with AUX heat
2
HEAT PUMP with 2stage AUX heat
3
2stg HEAT PUMP with AUX heat
4
2stg HEAT PUMP with 2stg AUX heat select F
Do not change he HVAC setup or HVAC selection switches if the
10
PG
HVAC
SETUP
HEAT
2
ND
STG
COOL
select A
select b
select C
select d
select E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents