Download Print this page

Kenwood KOS-V1000 Service Manual page 14

Advanced integration a/v controller
Hide thumbs Also See for KOS-V1000:

Advertisement

KOS-V1000/V500
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
41
PRE_MUTER
42
PRE_MUTEF
43
RELAY_SW1
44
RELAY_SW2
45
RELAY_SW3
46
RELAY_SW4
47
RELAY_DET1
48
RELAY_DET2
49
RELAY_DET3
50
RELAY_DET4
51
ILL_DET
52
PAK_DET
53
REV_DET
54
P_CON
55
BVDD
56
BVSS
57
ANT_CON
58
NC
59
PWIC_STBY
60
PWIC_MUTE
61
AUD_MUTEC
62
AUD_MUTEB
63
AUD_MUTEA
64
AUD_MUTE2
65
AUD_MUTE1
66
AUD_MUTE0
67
AUD_SDA
68
AUD_SCL
69
PON
70
LX_RST
71
AVDD
72
AVSS
73
AVREF
74
PWIC_DCDET
75
LINE_MUTE
76
NC
77
A_WRT_E2P
78
LX_MUTE
79
A_TYPE0
14
Application
PREout rear MUTE
PREout front MUTE
ON/OFF of external equipment relay control
ON/OFF of external equipment relay control
ON/OFF of external equipment relay control
ON/OFF of external equipment relay control
Detection of external equipment relay control
Detection of external equipment relay control
Detection of external equipment relay control
Detection of external equipment relay control
ILL detection
Parking detection
Reverse detection
P-CON control output
Power supply terminal
GND terminal
P-ANT control output
(Not used)
PWIC standby
PWIC_FR MUTE
E-VOL inputSEL_C MUTE
E-VOL inputSEL_B MUTE
E-VOL inputSEL_A MUTE
E-VOL center, SWMUTE
E-VOL rear MUTE
E-VOL front MUTE
E-VOL data output / ROM correction E2PROM communication
data input/output
E-VOL clock output / ROM correction E2PROM communication
clock output
A8V, V5V, SW5V ON/OFF
Hardware-reset to slave unit
Power supply terminal
GND terminal
Reference voltage input
SP_FR output DC offset detection
LINE-MUTE input detection
(Not used)
Used when writing E2PROM
MUTE request from slave unit
Destination (Voltage reading)
I/O
Note
O
O
O
O
O
Used only in KOS-V1000.
O
Used only in KOS-V1000.
I
I
I
Used only in KOS-V1000.
I
Used only in KOS-V1000.
I
I
I
O
-
-
O
O
O
O
O
O
O
O
O
O
I/O
O
O
O
-
-
-
I
I
-
I
I
I

Advertisement

loading

This manual is also suitable for:

Kos-v500