MD-E9000H
TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
• AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
Test Stage
Frequency
AM IF
450 kHz
AM Band
Coverage
AM Tracking 990 kHz
*1. Input: Antenna
*2. Input: Antenna
Frequency
Setting/
Instrument
Display
Adjusting
Connection
Parts
1,620 kHz
T351
*1
522 kHz
(fL): T306
*2
1.1 ± 0.1 V
990 kHz
(fL): T303
*1
Output: TP302
Output: TP301
AM BAND
COVERAGE fL
R356
TP302
T351
AM IF
Figure 22 ADJUSTMENT POINTS

ADJUSTMENT

• FM
Notes:
1: Description of the "FM IF Adjustment" is not carried on this
Manual. It is because the IF coil in the FM front end section
has been best adjusted in the factory so that its further
adjustment is not needed at the field. When replacing the
FM front end assembly, no adjustment is needed either.
2: The parts in the FM front end section are prepared in a
complete unit, so you can't obtain each part individually.
T306
R336
TP301
AM TRACKING
fL
TUNER PWB
– 22 –
T303
SO301
FM ANTENNA