Can be washed in the dishwasher. It must be washed when
every 4 months, or more frequently if use is particularly intense. Guaranteed to operate after
washing for up to a maximum of 5 times before requiring replacement. The Alarm signal, if it
has been activated, only appears when the Suction motor is turned on.

Activating the alarm signal

• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on
installation or at a later date.
• Turn the Lights and the Suction Motor off.
• Press and hold button E for 2 seconds:
• C flashes twice – Activated Charcoal Filter saturation alarm ACTIVATED.
• C flashes once – Activated Charcoal Filter saturation alarm DEACTIVATED.
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press and hold button G for 2 seconds.

Changing the Filter

• Remove the comfort panel.
• Remove the Metal grease filters.
• Remove the metal filter stops from the grease filter and clean
the saturated activated charcoal odour filter.
• Replace the clean activated charcoal filter, hooking it back up
to the grease filter using the metal filter stops.
• Replace the Metal grease filters.
• Close the comfort panel.
• For replacement contact technical support. ("To purchase con-
tact technical support")