Stanley PC809 Instruction Manual page 4

800 watt power inverter
Hide thumbs Also See for PC809:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION
Your inverter will provide you with continuous electrical power when powered by a reliable 12 volt DC source, such as a vehicle
battery or a multiple battery configuration. This manual does not describe all of the possible configurations.
mounting the Inverter
Tools Required: four BA4x14 screws in a set and Philips head screwdriver (NOT supplied).
The inverter comes equipped with mounting brackets for long-term installation. The manufacturer recommends using BA4x14
screws in a set with a standard Philips head screwdriver (none of these are supplied). User may choose to use different screws
appropriate to the mounting surface.
Secure the inverter to a flat surface, observing all cautions regarding installation found in this manual.
CAUTION
To avoid the risk of property damage, only mount the inverter on a level, stable surface, assuring that all screws are tightened
securely and observing all of the cautions and recommendations regarding installation found in this manual.
Operating Environment
For best operating results, your inverter should be placed on a flat surface, such as the ground, car floor or seat, or other solid
surface to help diffuse the heat that is generated. Position the inverter as close to the DC power source as possible.
The inverter should only be operated in locations that meet the following criteria:
DRY – Do not allow water and/or other liquids to come into contact with the inverter.
COOL – Ambient air temperature should be between 30°F (–1°C) non-condensing and 105°F (40°C). Do not place the inverter on
or near a heating vent or any piece of equipment that is generating heat above room temperature. Keep the inverter out of direct
sunlight.
vENTILATED – Allow at least three inches of clearance from other objects to ensure free air circulation around the inverter. Never
place items on or over the inverter during operation.
SAFE – Do not locate inverters in an area, room or compartment where explosives or flammable fumes might be present, such as
engine rooms, engine compartments, and boats or small, unvented battery compartments.
Connecting to a power Source Using the Supplied battery Clips with "O" Ring Connectors
Tools Required: a Philips head screwdriver (NOT supplied).
Use the provided battery clips (with cables and O-ring connectors) to connect the inverter directly to the 12 volt power source as
follows:
1. Make sure that no flammable fumes are present in the installation area.
2. Open the red (positive) plastic protective cap (downward). Using a Philips head screwdriver, unscrew the PM6x10 connection
screw (counterclockwise) and remove it.
3. Attach the positive O-ring at the end of the red battery clip cable to the positive connection post. Replace the connection
screw and screw it clockwise to secure. Do not over-tighten.
4. Open the black (negative) plastic protective cap (downward). Using a Philips head screwdriver, unscrew the PM6x10
connection screw (counterclockwise) and remove it.
5. Attach the negative O-ring at the end of the black battery clip cable to the negative connection post. Replace the connection
screw and screw it clockwise to secure. Do not over-tighten.
6. Make sure that all connections between cables and terminals are secure.
Direct hardwiring to power Source (optional connection method; hardware not included)
Use #8 AWG wire if the inverter-to-power source connection is 4 feet or less. For longer cable lengths, use #6 AWG wire for lengths
to 10 feet. For cable lengths exceeding 10 feet from inverter to battery, contact manufacturer for additional information. In either
case, protect the positive (+) wire from shorts by installing a 150 amp fuse or circuit breaker close to the DC power source (battery)
terminal. The cable, fuse holder and fuse (not supplied) can be purchased at an electrical supply company.
proCedure
1. Make sure that no flammable fumes are present in the installation area.
2. Identify the positive (+) and negative (–) DC power source (battery) terminals.
3. Install a fuse holder or breaker close to the positive (+) terminal of the DC source (battery).
4. Connect a length of wire on one side of the fuse holder or circuit breaker. Connect the other end of the wire to the positive (+)
terminal of the inverter.
5. Connect a length of wire between the inverter' s negative (–) terminal and the DC power source negative (–) terminal.
6. Connect a short length of wire to the other terminal of the fuse holder or circuit breaker. Mark it "positive" or "+".
7. Connect the free end of the fuse or breaker wire to the positive (+) terminal of the DC power source (battery).
8. Insert a fuse appropriate to the inverter in the fuse holder.
9. Test the inverter by turning it on and plugging in a 100 watt lamp or equipment.
10. If the inverter is not properly operating, then refer to the "Troubleshooting" section of this manual.
PC809_ManualENSP_032613.indd 6-7
6
CAUTIONS: TO REDUCE THE RISK OF PROPERTY DAMAGE
• Loose connectors may cause overheated wires and melted insulation.
• Check to make sure you have not reversed the polarity. Damage due to reversed polarity is not covered by manufacturer' s
warranty.
Important Cable InformatIon
Substantial power loss and reduced battery operating time results from inverters installed with cables that are not able to supply
full power. Symptoms of low battery power can result from cables that are either excessively long or an insufficient gauge.
OpERATING INSTRUCTIONS
Refer to "Power and Fault Indicators on the LCD Display" for an explanation of the operating and fault icons. If a fault icon appears,
refer to the "Troubleshooting" section.
The USB port is ready to use whenever the inverter is properly connected to a power source. To use the 120 volt AC outlets,
however, the inverter must be properly connect to a power source and the power button must be turned on.
CAUTION: TO REDUCE THE RISK OF PROPERTY DAMAGE:
Always connect the inverter to the 12 volt DC power source before plugging any devices into the unit.
The standard North American 120 volt AC and USB outlets allow simultaneous operation of multiple devices. Simply plug the
110/120 volt AC appliance into one of the inverter' s three-prong AC outlet and/or plug the USB-powered device into the inverter' s
USB charging port and operate normally.
Notes:
Ensure that the wattage of all equipment simultaneously plugged into the inverter does not exceed 800 watts continuous.
The inverter will not operate appliances and equipment that generate heat, such as hair dryers, electric blankets, microwave ovens and toasters.
This inverter' s USB Charging Port does not support data communication. It only provides 5 volts/500mA DC power to an external USB-powered device.
Remember to turn the unit off and disconnect from any power source when it is not in use.
CARE AND mAINTENANCE
Storage
1. Ideal storage temperature range is 0-40°C (32-104°F).
2. Store and use the inverter in a cool, dry place with adequate ventilation for all-around air circulation.
3. Avoid locations that are exposed to heating units, radiators, direct sunlight, or excessive humidity or dampness.
TROUbLEShOOTING
Common Audio/visual problems
buzzing Sound In Audio Systems
Some inexpensive stereo systems and boom boxes make a buzzing sound when operated from the inverter, because the power
supply in the electronic device does not properly filter the modified sine wave produced by the inverter. The only solution to this
problem is to use a sound system that has a higher quality power supply.
Television Interference
The inverter is shielded to minimize interference with Tv signals. however, in some instances, some interference may still occur,
particularly where Tv signals are weak. Try the following corrective measures:
• Place the inverter as far as possible from the television, the antenna and the antenna cables. Use an extension cable, if necessary.
• Readjust the orientation of the inverter, the antenna cables and the Tv power cord to minimize interference.
• Make sure the antenna feeding the television provides an adequate ("snow free") signal and that high quality, shielded antenna
cable is used.
• Do not use the inverter to operate high-power appliances or tools at the same time you are using it to operate the Tv.
Common power Output problems
Input voltage below 10.5 volts
Recharge auto battery or check DC power supply.
Equipment being operated draws too much power
Reduce load to maximum 800 watts.
Inverter in thermal shutdown condition
Allow inverter to cool down. Ensure there is adequate ventilation around the unit and that the load is no more than 800 watts for
continuous operation.
AC output is shorted
Unplug the AC appliance. Turn off the inverter. Disconnect the unit from any 12 volt DC power source. Check the appliance cord.
7
5/23/2013 1:09:46 PM

Advertisement

Table of Contents
loading

Table of Contents