Thermostat Chart - Single Stage Ac With Psc Furnace - York International TCHDSERIES Installation Manual

R-410a horizontal discharge 1.5 to 5 tons – 1 & 3 phase
Table of Contents

Advertisement

AC 5D
Single Stage Air Conditioner – Single Stage PSC Furnace
THERMOSTAT
*PP11C70224
Y
Full Stage Compressor
RH
24 – Volt Hot
(Heat XFMR)
G
Fan
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
HM1
Humidistat
Clipping Jumper W914 for
electric heat on thermostat
is not necessary
FIGURE 10: Thermostat Chart - Single Stage AC with PSC Furnace
Johnson Controls Unitary Products
TG(8/9)S
24VAC Humidifier
Relay
(Optional)
ID MODELS
TGLS
SINGLE STAGE
PSC
FURNACE
SINGLE STAGE PSC
FURNACE
C
24 – Volt Common
Y/Y2
Full Stage Compressor
R
24 – Volt Hot
G
Fan
W
Full Stage Heat
5320779-UIM-A-0417
SINGLE STAGE
AIR
CONDITIONER
SINGLE STAGE
SINGLE STAGE
AIR CONDITIONER
AIR CONDITIONER
C
24 – Volt Common
Y
Y
Compressor Contactor
Compressor
A0165-002