Technical Information - AEG F88722IM0P User Manual

Table of Contents

Advertisement

20
www.aeg.com
Problem and alarm code
Small leak from the appli-
ance door.
The appliance door is diffi-
cult to close.
Rattling/knocking sounds
from inside the appliance.
The appliance trips the cir-
cuit-beaker.
Refer to "Before first use",
"Daily use", or "Hints and
tips" for other possible
causes.
Once you have checked the appliance,
deactivate and activate the appliance. If

14. TECHNICAL INFORMATION

Dimensions
Electrical connection
Water supply pressure
Water supply
Capacity
Power consumption
Power consumption
1) Refer to the rating plate for other values.
2) If the hot water comes from alternative source of energy, (e.g. solar panels, aeolian energy), use the
hot water supply to decrease energy consumption.
Possible solution
• The appliance is not level. Loosen or tighten the adjust-
able feet (if applicable).
• The appliance door is not centred on the tub. Adjust the
rear foot (if applicable).
• The appliance is not level. Loosen or tighten the adjust-
able feet (if applicable).
• Parts of the tableware are protruding from the baskets.
• The tableware is not properly arranged in the baskets.
Refer to basket loading leaflet.
• Make sure that the spray arms can rotate freely.
• The amperage is insufficient to supply simultaneously all
the appliances in use. Check the socket amperage and
the capacity of the meter or turn off one of the applian-
ces in use.
• Internal electrical fault of the appliance. Contact an Au-
thorised Service Centre.
Width / height / depth (mm)
Voltage (V)
1)
Frequency (Hz)
bar (minimum and maximum)
kPa (minimum and maximum)
Cold water or hot water
Place settings
Left-on mode (W)
Off-mode (W)
the problem occurs again, contact an
Authorised Service Centre.
For alarm codes not described in the
table, contact an Authorised Service
Centre.
596 / 818 - 898 / 575
200 - 240
50 / 60
0.5 - 8
50 - 800
max 60 °C
2)
14
5.0
0.10

Hide quick links: