Download Print this page

Korg C-520LC Service Manual page 15

Advertisement

11
[ORGAN 2]
[STRINGS/PAD]
12
[CHOIR]
13
14
[REVERB]
[CHORUS]
15
16
[METRO]
[PART 1]
17
[PART 2]
18
[TRANSPOSDE]
19
[BRILLIANCE]
20
21
[DEMO]
[RECORD]
22
23
[PLAY/PAUSE]
24 All LEDs
25 All LEDs
26 All LEDs
27 All LEDs
28 All LEDs
29 All LEDs
30 All LEDs
31 All LEDs
32 All LEDs
33 All LEDs
34 All LEDs
3 Pedal Inspection
Step on the left, center, and right pedal in the order, when value of the A/D is normal,
the inspection proceeds to next automatically.
When all the 3 pedals are normal, C-520 proceeds to next inspection.
1 left pedal
2 center pedal
3 right pedal
4 Measurement of the maximum level
The sine wave of 1000Hz is output from the channel which is measured.
When R is not connected, the mixed signal (L+R) is output from L.
When measurering, connect cables to L and R.
When measuring of L, 660Hz signal is output from R. When measuring of R, 330Hz is output from L.
Push [METRONOME], then the inspection proceeds to the next step.
After Headphone2R, the inspection proceeds to the measurement of the noise.
When you do not measure, push {METRONOME] six times and proceed.
1 Lineout L
2 Lineout R
3 Headphone 1 L
4 Headphone 1 R
5 Headphone 2 L
6 Headphone 2 R
5 Measurement of noise level
When measuring, connect cables to both L and R.
Push [METRONOME], then inspection proceeds to the next step.
After Headphone "R, next is Measurement of the line input.
When you do not measure, push {METRONOME] 6times and proceed the inspection.
1 Lineout L
2 Lineout R
3 Headphone 1 L
4 Headphone 1 R
5 Headphone 2 L
6 Headphone 2 R
6 Measurement of the LINE INPUTS
When measuring, connect cables to both L and R.
Input -10[dBu] signal only to the input which you measure.
Push [METRONOME] to proceed to the next step.
After Lineout R, next is the confirmation of speaker sound.
When you do not measure, push [METRONOME] twice and proceed.
[ORGAN 2]
[STRINGS/PAD]
[CHOIR]
[REVERB]
[CHORUS]
[METRO]
[PART 1]
[PART 2]
[TRANSPOSDE]
[BRILLIANCE]
[DEMO]
[RECORD]
[PLAY/PAUSE]
[BANK]
[▲](up)
[▼](down)
[+/YES]
[EDIT]
[TEMPO+]
[SONG SEL]
[-/NO]
[EXIT]
[TEMPO-]
[STOP]
1.5 ~ 5.5 [dBu]
1.5 ~ 5.5 [dBu]
1.5 ~ 5.5 [dBu]
33 ohm load is needed.
1.5 ~ 5.5 [dBu]
33 ohm load is needed.
1.5 ~ 5.5 [dBu]
33 ohm load is needed.
1.5 ~ 5.5 [dBu]
33 ohm load is needed.
less than -88.0 [dBu]
less than -88.0 [dBu]
less than -85.0 [dBu]Needed 33 ohm load
less than -85.0 [dBu]Needed 33 ohm load
less than -85.0 [dBu]Needed 33 ohm load
less than -85.0 [dBu]Needed 33 ohm load