Huawei SUN2000-42KTL User Manual page 59

Hide thumbs Also See for SUN2000-42KTL:
Table of Contents

Advertisement

SUN2000-(36KTL,42KTL)
User Manual
Figure 5-19 Connecting DC input power cables
If the DC input power cable is reversely connected and the DC switches are ON, do not turn
off the DC switches immediately. Otherwise, the inverter may be damaged. The damage
caused by reverse connection of the DC input power cable is beyond the warranty scope. Wait
until the PV string voltage reduces to the safe range (below 60 V DC). Then, turn off the two
DC switches, remove the positive and negative connectors, and rectify the connection.
----End
Follow-up Procedure
Before removing the positive and negative connectors, ensure that the two DC switches are
OFF.
To remove the positive and negative connectors from the SUN2000, insert a removal wrench
into the notch and press the wrench with an appropriate force, as shown in
Issue Draft A (2016-05-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Connecting Cables
Figure
5-20.
53

Advertisement

Table of Contents
loading

Table of Contents