xComfort Room Controller Touch

User Manual

xComfort Room Controller Touch User Manual 1v00_EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the xComfort and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton xComfort

  • Page 1: User Manual

    Room Controller Touch User Manual xComfort Room Controller Touch User Manual 1v00_EN...
  • Page 2 Pro další jazyky informace o xComfort návštěvy • www.eaton.eu/xcomfort nebo www.xcomfort.cz nebo použijte QR kód. Voor andere talen en meer informatie over xComfort ga naar • www.eaton.nl/xcomfort of www.xcomfort.nl of maak gebruik van de QR-code xComfort Room Controller Touch User Manual 1v00_EN...
  • Page 3: Table Of Contents

    2.7.2 (Optional) Edit Week Program Timer ..................13 2.7.3 (Optional) Edit humidity Set-point ..................15 2.7.4 (Optional) Edit/Set Current Time and Date ................16 2.7.5 (Optional) Edit/Set Monthly clock correction factor ............... 17 xComfort Room Controller Touch User Manual 1v00_EN iii | P a g e...
  • Page 4 Room Controller Touch User Manual 1v00_EN iv | P a g e...
  • Page 5: Introduction

    Sensor mode; in which the Room Controller Touch registers the room climate conditions and the • user settings and sends them to an intelligent device, e.g. xComfort Smart Home Controller (SHC), which actually controls the climate in the room. Since the transmission of radio signals is based on a non-exclusive communication channel, interference to the transmission are possible.
  • Page 6: The Room Controller Touch

    To maximize the battery life, a delay between the information on the display in the idle- Note: state and the actual status in the xComfort SHC is possible. The maximum possible delay can be reduced by the installer, but this will lead to a reduction in the battery life. In other configurations the display always contains the latest information.
  • Page 7: Cleaning Mode

    Used batteries should not be disposed of with regular domestic waste. They should be taken to a battery disposal point. Never recharge standard batteries!! This entails a risk of explosion. Do not throw the batteries into fires Do not short-circuit batteries xComfort Room Controller Touch User Manual 1v00_EN P a g e...
  • Page 8: Operation Mode

    On touching the display again it enters the Active-state. In this state, the backlight is switched on, and when connected to the xComfort SHC, the information is refreshed to get the latest status. 2.4.1 Basic operations Show the current temperature •...
  • Page 9: Basic Operating Instructions

    The active set-point temperature is the sum total of the active pre-defined operation mode set-point temperature and the temporary adjustment (increase or decrease) that is made. Initial Step 1 (Optional) Select the Heating or Cooling set-point Idle Timeout xComfort Room Controller Touch User Manual 1v00_EN P a g e...
  • Page 10: Temporarily Adjust The Current Set-Point Temperature

    The pre-defined set-points can also be used in the Week Program (when enabled) to switch automatically between the different set-point temperatures on a timed basis, Note: The Week Program will be switched OFF when the active set-point temperature (operation mode) is changed manually. xComfort Room Controller Touch User Manual 1v00_EN P a g e...
  • Page 11: Show Room Humidity

    Control mode The option is available in control mode if, during installation, the external temperature sensor input is configured for use as an outdoor temperature sensor. xComfort Room Controller Touch User Manual 1v00_EN P a g e...
  • Page 12: Show Time And Day Of Week

    The Touch-buttons of the Room Controller Touch can be used as push buttons to control the lights, shutters/blinds in the room, for example, or to trigger Scenes in the xComfort SHC. To get the Touch-buttons, an actuator or intelligent device must be connected to the Note: Touch-button of the Room Controller during the installation.
  • Page 13: Enhanced Operating Instructions

    Week Program is available in the control mode only. Sensor mode In the Sensor mode the option is available when connected with the xComfort SHC (e.g. Room Manager), otherwise the Week Program is not available. If the Week Program is activated (ON), then the operation mode will switch to the correct Note: operation mode according to the week program for the current time.
  • Page 14: Optional) Selecting Heating And/Or Cooling Mode

    Sensor Mode If the Room Controller is connected to an xComfort SHC, it is possible to change manually between ‘heating’, ‘cooling’ and ‘OFF’. In this case, the ‘Heating&Cooling’ mode is not available. When connected to a Room Manager the temperature regulation mode cannot be changed.
  • Page 15: Edit Operating Instructions

    Comfort or Day mode. Factory default value 21°C/24°C (or 0K with Room Manager) Sensor mode When connected to the xComfort SHC, the values of the pre-defined temperature are the same as the set-point temperatures in the SHC. Making a manual change on the Room Controller Touch will also change the set-point in the SHC (and v.v.).
  • Page 16 Optional Select the Set-point Optional Select the Heating or Cooling Set-point Step 3 (Change) Changed value is flashing Leave Edit mode Step 4 Timeout or Idle Timeout xComfort Room Controller Touch User Manual 1v00_EN 12 | P a g e...
  • Page 17: Optional) Edit Week Program Timer

    Step 4 (Enter Program edit) The Day of week and Trigger point are flashing Enter Edit Program Select Day of Week Selected Day of the Week is flashing xComfort Room Controller Touch User Manual 1v00_EN 13 | P a g e...
  • Page 18 Step 1 (Select) Minutes are flashing Step 2 (Change) To Change the Time hours Change Time Hour Step 1 (Select) Hours are flashing Step 2 (Change) xComfort Room Controller Touch User Manual 1v00_EN 14 | P a g e...
  • Page 19: Optional) Edit Humidity Set-Point

    ON command if the actual humidity is below the set-point value. The set-point value can be changed manually. Initial select Humidity Edit mode Enter Change xComfort Room Controller Touch User Manual 1v00_EN 15 | P a g e...
  • Page 20: Optional) Edit/Set Current Time And Date

    The option to set the Time and Date manually with the Room Controller is not available if the Room Controller is connected to an xComfort SHC. In this case, the time and date are synchronized with the xComfort SHC date and time.
  • Page 21: Optional) Edit/Set Monthly Clock Correction Factor

    The option is only available if the clock function is enabled during the installation and if the Room Controller does not receive the time and date from another device. xComfort Room Controller Touch User Manual 1v00_EN 17 | P a g e...
  • Page 22 Initial select clock Enter Edit Press Edit > 5 Sec Change Leave Edit xComfort Room Controller Touch User Manual 1v00_EN 18 | P a g e...
  • Page 23 Room Controller Touch User Manual 1v00_EN 19 | P a g e...