8.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at "software download" on the "Support Information from NWBG/VDBG-AVC" web-site in
"TSN system", together with Maintenance software.
8.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
No.
Parts No.
1
RFKZ0416
2
RFKZ0416
3
VFK1364
4
VFK1174
8.3.1.
Extension Cable Connections
Table S1 Extension Cable List
Connection
FP9003 (Main P.C.B.) - Lens with CCD unit (CCD section)
FP9002 (Main P.C.B.) - Lens with CCD unit (Lens section)
FP9001 (Main P.C.B.) - FT6301 (Top P.C.B.)
FP9004 (Main P.C.B.) - Rear Operation P.C.B.
35
Form
41PIN 0.3 FFC
41PIN 0.3 FFC
14PIN 0.5 FFC
16PIN 0.5 FFC