FEC U121TA User Manual

FEC U121TA User Manual

Usb aegis series

Advertisement

USB Aegis
Series

Advertisement

Table of Contents
loading

Summary of Contents for FEC U121TA

  • Page 1 USB Aegis Series...
  • Page 2: Table Of Contents

    USB Aegis – Series Table of Content Features ..................3 Specifications ................4 Dimensional Diagrams ............... 5 Exploded View Diagram ............. 6 What is provided with the USB Aegis ........7 Switch and Controls..............8 OSD Settings................9 USB-to Serial Driver Installation ..........14 ELO Touch Tools Installation ..........
  • Page 3 USB Aegis – Series The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
  • Page 4: Features

    USB Aegis – Series Features Cast aluminium front and base construction - rugged and durable Compact size and small footprint - fits where space is at a premium Standard VGA for easy interface to a standard PC VGA port. (1) Wireless Wi-Fi LAN 802.11b (optional) (2) USB upstream port for connection to host PC.
  • Page 5: Specifications

    U152TA=12v @ 4A and U12xTA=12v @2A Weight U152TA=6.4 kg and U12xTA= 5.5 Kg Please note that the “x” denotes model specific options, e.g. U121TA standard brightness and U122TA is high brightness. The “T” means with Touch Screen, and the “A” stands for Analog.
  • Page 6: Dimensional Diagrams

    USB Aegis – Series Dimensional Diagrams U12xTA U152TA...
  • Page 7: Exploded View Diagram

    USB Aegis – Series Exploded View Diagram...
  • Page 8: What Is Provided With The Usb Aegis

    USB Aegis – Series What is provided with the USB Aegis Upon unpacking, please inspect to make sure all items are in place and in good condition. If there is any damaged or missing item, please contact your dealer immediately. The following items come as standard 1.
  • Page 9: Switch And Controls

    USB Aegis – Series Switch and Controls Model U152TA / U12xTA has built-in OSD (on screen display) controls to adjust various display parameters. The control buttons are located on the bottom of the back cover.
  • Page 10: Osd Settings

    USB Aegis – Series OSD Settings There are four buttons on OSD panel: Menu / Enter, Right, Left and LCD ON/OFF. The functions of these four buttons are as follows Menu/Enter Button Press it to open OSD window and enter user mode to do the function adjustment or selection of the item.
  • Page 11 USB Aegis – Series OSD Menu Structure Functions include: [Brightness] [Contrast] [Exit] This item will adjust the brightness of the screen. This function will adjust the offset value of ADC. Setting this value too high or too low will destroy the quality of image. Values are from 0 to 255 This item will adjust the contrast of the screen.
  • Page 12 USB Aegis – Series Functions include: [Auto color] [S RGB] [Color temp] [Exit] This item will automatically adjust color. Standard RGB mode This item includes user colors 4200K, 5000K, 6500K, 7500K, 9300K. RGB User color values are from 0 to 255. Press the EXIT key to upper level.
  • Page 13 USB Aegis – Series Functions include: [Auto adjust] [Extend screen] [Phase adjust] [H position adjust] [V position adjust] [Exit] This item will automatically adjust the H/V position, frequency, phase, and black level. Extend screen in display. Value from 0 to 100 This item will adjust the sampling Phase.
  • Page 14 USB Aegis – Series Functions include: [OSD detail] [Factory reset] [Sharpness] [640 / 720] [Exit] OSD detail function, include OSD maintain time (Value from 0 to 60), OSD icon H/V position adjust (Value from 0 to 100). Factory reset, press this item to load default value. Sharpness function.
  • Page 15: Usb-To Serial Driver Installation

    USB Aegis – Series USB-to Serial Driver Installation 1. Insert the FEC Utility CD and Locate D:\Usb-Aegis\PL-2303HX 2. Select the relevant operating system folder that you are using. 3. Shown below are self-explanatory examples for Windows 2k & XP.
  • Page 16: Elo Touch Tools Installation

    ELO Touch Tools Installation ELO Touch Tools Installation for all Windows Operating Systems 1. Insert the FEC Utility CD and Locate D:\TOUCHSCREEN 2. Select the relevant ELO folder for the operating system that you are using. Example. If you are installing for a Windows 98 system, then select EloWin98.
  • Page 17 USB Aegis – Series 3. Select if you have one or two monitors and click Next. 4. Select the COM port for the monitor. It is recommended that you select COM3 for primary touch screen and COM4 for second touch screen. Press Next.
  • Page 18 USB Aegis – Series 5. Wait until the ELO Touch Tools have been installed. 6. Select View ELO touch screen control panel and click Finish. The Host PC will reboot automatically. After the Host has rebooted, follow the directions to calibrate the touch screen.
  • Page 19 USB Aegis – Series ELO Control Panel This section explains the different options in the ELO control Panel. General tab The general tab allows you to: Change the COM port your touch screen is set to. Calibrate the touch screen with the Align button...
  • Page 20 USB Aegis – Series Buttons tab The Buttons tab allows you to: Adjust all mouse emulation controls. Change cursor properties. Enable or disable right mouse button utility.
  • Page 21 USB Aegis – Series Sound tab The Sound tab allows you to: To change sound properties for ELO touch tools.
  • Page 22 USB Aegis – Series Diagnostics tab The Diagnostics tab allows you to: View Controller Information. About tab The About tab displays Information about ELO Touchsystems...
  • Page 23: I/O Board Configuration

    USB Aegis – Series I/O Board Configuration There is only 1 physical main I/O board (9000PB0650) This I/O board connects all secondary I/O boards, devices and ports. The following diagrams and tables explain in detail the connector assignments and uses. bottom side I/O Bus connector 9000PB0650 I/O Board...
  • Page 24 At document creation time, the MSR used in the diagram below is a specific type and is not interchangeable with other MSR modules used with other FEC POS models. The reason being, if you need to reprogram the MSR for country specific or special formatting, then it has to be programmed via a USB connection.
  • Page 25 USB Aegis – Series VGA1 VGA port PIN No. Description GREEN BLUE SM DATA SM CLK V-SYNC H-SYNC CON1 USB to RS232 port PIN No. Description RI/DC output (RI is the default setting)
  • Page 26 USB Aegis – Series CON2 USB 2.0 downstream port PIN No. Description USB2.0_2- USB2.0_2+ CON3 POWERED USB 2.0 downstream port PIN No. Description PIN No. Description USB2.0_1- +12V USB2.0_1+ +12V CON4 USB 2.0 upstream port PIN No. Description USB2.0_0- USB2.0_0+ DC port (DC +12V inport) PIN No.
  • Page 27 USB Aegis – Series I/O Bus connector PIN No Description PIN No Description KB-CLK AGND KB-DATA PC-CLK PC-DATA H-SYNC V-SYNC SM DATA BLUE SM CLK GREEN AGND USB_2+ USB_2- AGND USB_3+ USB_3- AGND USB2.0_4+ USB2.0_4- AGND +12V AGND RS232 Power selector Jumpers PIN No.
  • Page 28: Hardware Installation

    USB Aegis – Series Hardware Installation Model U152TA / U12xTA 1. Turn off the computer. 2. Put the USB Aegis on a steady surface. 3. (Please refer to the External Power Adapter section for instruction on using an external power adapter and skip this step). Powering from the host computer through the Power Bracket: a.
  • Page 29 USB Aegis – Series 錯誤!
  • Page 30: External Power Adapter (Optional)

    USB Aegis – Series External Power Adapter (optional) For situations where the Power Bracket cannot be used to power the USB Aegis, an optional External Power Adapter can be used instead. 1. Check the items in the External Power Adapter kit, including a power adapter and an AC cord.
  • Page 31: Mcr Installation

    USB Aegis – Series MCR Installation Please note: throughout this document references are made to MCR and MSR, they are in fact the same thing. (MCR = Magnetic Card Reader) (MSR = Magnetic Stripe Reader) The MCR option can be fitted to the right side of USB Aegis. This option allows the reading of magnetic stripe card through keyboard input.
  • Page 32 USB Aegis – Series 1. Check the items in the MCR option kit. 2. Turn off Power to the USB Aegis and the computer. 3. Remove the MSR cover plate that can be found on the right side and to the rear of the main Unit...
  • Page 33 USB Aegis – Series...
  • Page 34 USB Aegis – Series 4. Attach the MCR Assembly to the main unit and connect the MCR cable to the MCR socket. 5. Secure the MCR to the main unit with 2 screws. 6. Turn on USB Aegis power. 7. Put the back cover on USB Aegis and secure with screws. * If the MCR is taken off, the loopback plug must be re-inserted.
  • Page 35: Mcr Parameter Modification

    USB Aegis – Series MCR Parameter Modification This option is for users who need to customize the MCR parameters for a particular task. Some of the useful parameters include: The selection of country code, other than the default English. The choice of track combinations. The preamble/postamble codes.
  • Page 36 USB Aegis – Series MCR Utility Reader...
  • Page 37: Vfd Customer Display Installation

    USB Aegis – Series VFD Customer Display Installation 1. Check the items in the VFD Customer Display Kit.
  • Page 38 USB Aegis – Series 2. Turn off power to USB Aegis and to the computer. 3. Remove the VFD Mounting Cover from the Base of USB Aegis.
  • Page 39 USB Aegis – Series 4. Secure the VFD Mounting Coupler to the Base with three VFD Mounting Screws.
  • Page 40 USB Aegis – Series 5. Thread the RJ-45 phone connector of the VFD Signal Cable through the VFD Mounting Coupler, from the bottom of USB Aegis. 6. Plug the RJ-45 connector into the VFD Customer Display.
  • Page 41 USB Aegis – Series 7. Fit the VFD Customer Display onto the VFD Mounting Coupler. 8. Plug the DB9M connector of the VFD Signal Cable to the external RS232 COM port on the main I/O board 9000PB0650. 9. Remove the base cover to expose the 9000PB0650 I/O board. 10.
  • Page 42: Trouble Shooting

    USB Aegis – Series Trouble Shooting When encountering difficulties in using this product, please follow the steps below. If the problem persists, please contact the dealer. 1. No picture on screen a. Check the AC cord and signal cable. Make sure they are properly connected.

This manual is also suitable for:

U122taU152ta

Table of Contents