Check Power - Panasonic KX-TGC210LAB Service Manual

Table of Contents

Advertisement

KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB

10.1.1. Check Power

10.1.1.1. Base Unit
Is the AC Adaptor inserted into AC outlet? (*1)
Is output voltage of AC adaptor 5.5 V?
Check VDDC (1.2 V): Test Point [VDDC]
RSTN: Reset = "High"?
Check Xtal CLK = 13.824 MHz?
Check BBIC.
Cross Reference:
Power Supply Circuit/Reset Circuit (P.13)
10.1.1.2. Handset
Is the battery inserted BATT+ and BATT-?
Is the voltage of BATT+ 2.3 V more?
Is the voltage of +1.8V about 1.8 V?
Is the voltage of CP3V about 3.0 V?
Is the voltage of CP4V about 4.0V ?
(When LED is On)
Does BBIC (IC1: 7) oscillate at 10.368 MHz?
Check BBIC (IC1).
Cross Reference:
Power Supply Circuit/Reset Circuit (P.13)
YES
OK
YES
YES
YES
YES
YES
YES
YES
YES
NO
AC Adaptor.
Check
NO
Check Power Supply Circuit.
NO
Check Reset Circuit.
NO
Check X501.
Note:
BBIC is IC501.
(*1) Refer to Specifications (P.7) for part number and
supply voltage of AC adaptor.
(*2) Refer to Base Unit (Main) (P.69).
NO
Check F1 is not open.
Check the battery and around BATT+ and
BATT- are not shorted.
NO
Check Power Supply Circuit/Reset Circuit .
NO
NO
Check BBIC (IC1).
NO
Check X1.
30