1-6. Current consumption ........................7 1-7. IrDA Test ............................7 1-8. Test program ...........................8 1. Standard test program (including QV-770 Built in ROM) ............8 2. Special test program (including QV-770 Built in ROM) ............12 Battery check ..........................12 Key check ..........................13 Last memory set ........................13 2.
SPECIFICATIONS Item Specification Recording System Digital (JPEG base); PC Link software can be used to input images in CAM, JPEG, TIFF and other format. Signal System NTSC Recording Medium Flash memory (4 MB) Memory Capacity FINE; 30 images (Approx. 124 KB compressed) NORMAL;...
Execute when replacing camera unit Load parameter in memory of camera unit. (Light box not needed.) (1) Set QV-770 to “PLAY” mode. (Computer communication does not work in “REC” mode.) (2) Connect QV-770 and PC with link cable RS-232. (3) Operate adjustment software on MS-DOS.
To correct this use the data next to this. • Perform this adjustment after loading color parameters. (1) Set QV-770 to “REC” mode. (2) Start test program. (Refer to “1-8. Test program”.) (3) Choose “DEFECT CORRECT” from test program and execute.
(2) Monitor the trigger waveform on digital oscilloscope and check the display. (3) Automatically recharged after shooting picture. Make sure that the DC in 6.0 V current does not exceed 1.2 A. (4) Set QV-770 to “PLAY” mode and check the display. Should not be white or too dark. Voltage Regulator DC6.0±0.1V...
Page 8
Strobe trigger waveform : 1 µ sec/DIV 1. Normal waveform TIME VOLTS : 1 V/DIV 757µV 1µV UERT First positive pulse. OK if second positive pulse is shown. First negative pulse. REPET SAVE ON ACQUIRE ON | OFF ON | OFF NORMAL ENVELOPE 2.
Notes: • (1) and (2) should look alike. (3) should be darker than (2). • (1) and (2) should not be white or too dark. • QV-770 and test chart (Material that does not reflect) should be 70 cm apart. Strobe lens...
3. BATTERY CHECK 4. KEY CHECK 5. LAST MEMORY SET 1. Standard test program (including QV-770 Built in ROM) (1) Turn power on while pressing “DISP” and “SHUTTER” buttons. (2) “WELCOME!” appears on the display followed by TEST MODE display.
Page 11
(1) Transaction (2) Display (4) Supplement (3) Check Utilized for brightness volt- 1. 10-step black Displays black and white Displays 10-step black and white bar on the When checking with an os- and white display bar gradated in 11 steps LCD and TV monitor age and contrast adjust- cilloscope, terminate it with...
Page 12
(1) Transaction (2) Display (4) Supplement (3) Check 6. Black color display Returns to Test mode dis- Provides black signal to Displays black on LCD and TV monitor. play by [+] or [-] buttons. LCD and TV monitor (Black level of VIDEO standard) Disables Auto Power Off Normal REC or PLAY modes The unit returns to normal...
Page 13
(1) Transaction (2) Display (4) Supplement (3) Check This mode is disabled when 9. IR TEST SLAVE Used for IrDA test together The unit does not show any FACTORY TEST display with IR TEST MASTER. This change on the display since the unit is turned off.
2. Special test program (including QV-770 Built in ROM) (1) Turn power on at REC mode, then press “Mode” button twice and change to “Serial Recording mode” then turn power OFF. (2) Turn power on while pressing “DISP“ button and “SHUTTER” button.
CP100 = 5.0 ± 0.05 [V] (You can use an AC adaptor however, for the checking after repairs, apply above mentioned voltages.) 1. Set QV-770 to “PLAY” mode. (Computer communication does not work in “REC” mode.) 2. Connect QV-770 and PC with link cable.
(1) Monitoring CP710 (HDB) with a frequency counter, adjust VR720 so that the frequency will be 15.734 ± 0.1 [KHz]. Notes: • Disconnect CP705 and CP700, then connect PCB-LA and make sure CP705 (CSY) and CP710 (HDB) are synchronized. • Keep room temperature at 20 ± 10°C. QV-770 PCB-LB VCC2 (CP181) VCC8...
(1) Apply 5.0 ± 0.05 V to VCL0 and adjust VR900 so that CP901(VBL) will be 6.1 ± 0.1 V. Notes: • Make sure that the current consumption is not abnormally large. • CN920 is open. QV-770 PCB-LA VCL0 (CP101) (CP901) 3.3 V...
(4) Keep waveform B at 2.1 ± 0.05V by adjusting Bright VR (VR304). (5) Keep waveform C at 2.9 ± 0.05V by adjusting contrast VR (VR303). Note: • Make sure that waveforms are not distorted. QV-770 3.3 V PCB-LA Waveform B...
(You can use an AC adaptor however, for the checking after repairs, apply above mentioned voltages.) (1) Adjust VR301 so that the second and third pulses of VB (CP324) signal level will be the same. Notes: • Perform this adjustment after contrast adjustment. • Trigger FRP (CP305). QV-770 3.3 V PCB-LA 1 2 3 4...
DISASSEMBLY Numbers in the parethesis correspond to the numbers in EXPLODED VIEW. 1. Unscrew two screws (S1) on the bottom of the camera. two screws (S1) 2. Rotate the camera unit and unscrew two screws (S1). Open console cover (2), then unscrew two screws (S1). two screws (S1) two screws (S1) 3.
Page 24
4. Disconnect two flexible cables from PCB-DA ass’y and remove two connectors from PCB-L ass’y. connector flexible cable 5. Disassembly of upper case. Remove flexible cable from PCB-L ass’y, then remove SUB773-LB2 ass’y. flexible cable Unscrew four screws (S2) fixing PCB-L ass’y then remove it. four screws (S2) —...
Page 25
Unscrew three screws (S2) fixing backlight, then remove the backlight. three screws (S2) When assembling, make sure to put each sheet in order. diffusion sheet (10) filter sheet (9) LCM spacer (8) Remove two screws (S2) fixing PCB-K773-KB ass’y (20), then remove PCB-K773-KB ass’y (20). two screws (S2) Remove LCD (6).
Page 26
6. Disassembly of Main case. Unscrew two screws (S4) fixing camera unit, then remove camera unit. two screws (S4) Remove PCB-K773A-KA (43). Unscrew two screws (S4) fixing PCB-K773-DA ass’y (24), then remove PCB-K773-DA ass’y (24). two screws (S4) — 24 —...
Page 27
7. Disassembly of Camera Unit. Unscrew one screw (S1), then disassemble as shown. one screw (S1) When assembling convex part of CCD should be placed with concave part of F knob. convex part concave part Unscrew one screw (S3) and disconnect two flexible cables, them remove CCD unit. one screw (S3) —...
Page 34
ACCESSORY I t e m Code No. Parts Name Specification Applicable 1014 9871 CASE/SOFT SC-773 5861 3578 STRAP ST-K775 1014 8773 CORD/VIDEO VC-K723-FC Notes: Q – Quantity used per unit R – Rank — 32 —...
TROUBLE SHOOTING Trouble 1 : No display • LCD connector or BL connector is OPEN. Insert connector. If broken, replace it. Trouble 2 : Erratic display when using strobe. • Interruption when using strobe. Refer to “1-4. Strobe check”. Trouble 3 : Cannot switch between REC/PLAY. •...
Page 46
CASIO TECHNO CO.,LTD. Overseas Service Division 8-11-10, Nishi-Shinjuku Shinjuku-ku, Tokyo 160-0023, Japan...