Mitsubishi Electric Q64RD User Manual page 12

Rtd input module; channel isolated rtd input module; gx configurator-ti (sw1d5c-qtiu-e)
Hide thumbs Also See for Q64RD:
Table of Contents

Advertisement

3.4.10 Setting range 1 (Q64RD-G) (Un\G20) ............................................................................................ 3-31
3.4.11 Setting range 2 (Q64RD-G) (Un\G21) ............................................................................................ 3-31
3.4.12 Warning output enable/disable setting (Un\G47) ........................................................................... 3-32
3.4.13 Warning output flag (Un\G48) ......................................................................................................... 3-32
3.4.14 Disconnection detection flag (Un\G49) ........................................................................................... 3-33
3.4.15 CH scaling value (Un\G50 to 53) ................................................................................................ 3-34
3.4.16 CH measured temperature value (32 bit) (Un\G54 to 61) .......................................................... 3-35
3.4.17 CH scaling range upper/lower limit values (Un\G62 to 77) ........................................................ 3-35
3.4.18 CH scaling width upper/lower limit values (Un\G78 to 85) ......................................................... 3-35
3.4.19 CH warning output upper/lower limit values (Un\86 to 101) ....................................................... 3-36
3.4.20 CH offset/gain temperature set value (Un\G118 to 133) ............................................................ 3-37
3.4.21 Extended averaging processing specification (Un\G134) ............................................................. 3-38
3.4.22 Conversion setting for disconnection detection (Un\G148) ........................................................... 3-39
3.4.24 Mode switching setting (Un\G158 to 159) ...................................................................................... 3-40
offset/gain resistance value (Un\G160 to 255) .............................................................................. 3-41
4.1 Handling Precautions ............................................................................................................................... 4- 1
4.2 Setup and Procedures before Operation ................................................................................................ 4- 2
4.3 Part Names and Settings ......................................................................................................................... 4- 3
4.4 Wiring........................................................................................................................................................ 4- 4
4.4.1 Wiring instructions ............................................................................................................................. 4- 4
4.4.2 External wiring ................................................................................................................................... 4- 5
4.5 Switch Setting for Intelligent Function Module ........................................................................................ 4- 7
4.6 Offset/Gain Setting ................................................................................................................................... 4- 9
5.1 Utility Package Functions ........................................................................................................................ 5- 1
5.2 Installing and Uninstalling the Utility Package ........................................................................................ 5- 3
5.2.1 Handling precautions ........................................................................................................................ 5- 3
5.2.2 Operating environment...................................................................................................................... 5- 5
5.3 Utility Package Operation ........................................................................................................................ 5- 7
5.3.1 Common utility package operations ................................................................................................. 5- 7
5.3.2 Operation overview ........................................................................................................................... 5- 9
5.3.3 Starting the Intelligent function module utility ................................................................................... 5-11
5.4 Initial Setting ............................................................................................................................................. 5-13
5.5 Auto Refresh Settings .............................................................................................................................. 5-14
5.6 Monitoring/Test ........................................................................................................................................ 5-16
5.6.1 Monitor/test screen ............................................................................................................................ 5-16
5.6.2 Offset/gain setting operation (Function version C or later) .............................................................. 5-19
5.6.3 Offset/gain setting operation (Function version B) ........................................................................... 5-20
5.6.4 OMC (Online Module Change) refresh data .................................................................................... 5-22
A - 10
4- 1 to 4-14
5- 1 to 5-23
A - 10

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Q64rd-g

Table of Contents