Admag AXF User Manual

Magnetic flowmeter; integral flowmeter/remote flowtube

Advertisement

Quick Links

User's
Manual
Please use the attached sheets for the pages listed below in IM 01E20D01-01E (10th).
Page and Item
Page 1-2, 1-3
1.1 Using the Magnetic Flowmeter Safety
Page 1-4, 1-5, 1-6
1.3 Combination Remote Converters
1.4 ATEX Documentation
Page 3-3
Figure 3.2.1, Lifting Flowmeter
Page 4-4
(3) Precautions for Wiring of Power
Supply Cables
Page 4-6
Figure 4.1.10, 4 to 20 mA DC Output
Connection
Figure 4.1.12, Active Pulse Output Con-
nection (Optional code EM)
Page 4-8
4.2 Wiring the Remote Flowtube
Page 6-10
Withstand Voltage
Page 6-11
Safety Requirement Standards
Page 8-5
8.3 CSA
Y okogawa Electric Corporation
AXF
Magnetic Flowmeter
Integral Flowmeter/
Remote Flowtube
[Hardware Edition]
Added the warning notes in (1) installation, (3)
Operation, and (4) Maintenance.
Changed the page number.
Changed the page number.
Added another horizontal position figure.
Changed the numbers of "IEC" in warning note.
Changed the value of maximum load resistance.
Changed the figure.
Added the important note on "wiring".
Changed the values of the withstand voltage.
Added the number of "EN" standard.
Changed the number of Applicable Standard
in (1) Technical Data.
Manual Change No. 13-009-E
Contents of Correction
Aug. 30, 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AXF and is the answer not in the manual?

Questions and answers

Summary of Contents for Admag AXF

  • Page 1 User’s Manual Magnetic Flowmeter Integral Flowmeter/ Remote Flowtube [Hardware Edition] Manual Change No. 13-009-E Please use the attached sheets for the pages listed below in IM 01E20D01-01E (10th). Page and Item Contents of Correction Page 1-2, 1-3 1.1 Using the Magnetic Flowmeter Safety Added the warning notes in (1) installation, (3) Operation, and (4) Maintenance.
  • Page 2: Using The Magnetic Flowmeter Safely

    1. INTRODUCTION • All procedures relating to installation must IMPORTANT comply with the electrical code of the country where it is used. An IMPORTANT sign denotes that attention is required to avoid damage to the instrument or system failure. (2) Wiring WARNING •...
  • Page 3: Warranty

    Trademarks: • The protective grounding must be connected ADMAG, AXF and ADMAG AXF are registered to a suitable IS grounding system. trademarks of Yokogawa Electric Corporation. • Take care not to generate mechanical spark Company names and product names used in this...
  • Page 4: Combination Remote Converters

    1. INTRODUCTION 1.3 Combination Remote Converters IMPORTANT • The AXF remote flowtube (size 2.5 (0.1 in.) to 400 mm (16 in.)) should be used in combina- tion with one of the following converters: - AXFA11 remote converter - AXFA14 remote converter...
  • Page 5: Atex Documentation

    1. INTRODUCTION 1.4 ATEX Documentation This procedure is only applicable to the countries in Kaikkien ATEX Ex -tyyppisten tuotteiden käyttöhjeet European Union. ovat saatavilla englannin-, saksan- ja ranskankielisinä. Mikäli tarvitsette Ex -tyyppisten tuotteiden ohjeita omalla paikallisella kielellännne, ottakaa yhteyttä lähimpään Yokogawa-toimistoon tai -edustajaan. All instruction manuals for ATEX Ex related products are available in English, German and French.
  • Page 6 1. INTRODUCTION IM 01E20D01-01E...
  • Page 7: Handling Precautions

    3. INSTALLATION • Mounting orientation CAUTION In order to lift a magnetic flowmeter that is fitted IMPORTANT with eyebolts, proceed as in Figure 3.2.1. Never If electrodes are perpendicular to the ground, air lift it using a bar passed through the flowtube as bubbles near the top or precipitates at the this damages the liner severely.
  • Page 8 N/– terminal: connect – CAUTION Be sure to connect the protective grounding of the AXF integral flowmeter with a cable of 2mm IMPORTANT or larger cross section in order to avoid electrical Do not connect power supply with 100 to 240 V...
  • Page 9 For pulse output from the DO terminals, param- eters must be set. Refer to “Parameter Descrip- 4 to 20 mA DC Current Output tion” in the user’s manual of the AXF Integral Flowmeter [Software Edition] (IM 01E20C02- AXF integral flowmeter 01E).
  • Page 10: Wiring The Remote Flowtube

    4. WIRING 4.2 Wiring the Remote • Ground the remote flowtube and the converter separately. Flowtube • Cover each shield of the signal cable with vinyl tube or vinyl tape to avoid contact between two This section describes the wiring of the remote shields or between a shield and a case.
  • Page 11 6. OUTLINE Polyurethane Rubber /Natural Soft Rubber / Size 2200 mm (88 in.) to 2600 mm (104 in.) EPDM Rubber Lining: % of Rate Standard Accuracy Flow Velocity Size mm (in.) V m/s (ft/s) (Calibration code B) 0.3 (1.0) 1.0 mm/s 25 (1.0) High grade Accuracy High grade Accuracy...
  • Page 12 6. OUTLINE ■ NORMAL OPERATING CONDITIONS CAUTION Ambient Temperature: –40° to +60°C (–40° to +140°F) *1: When performing the Insulation Resistance Test or the *1: Minimum temperature should also be limited according Withstand Voltage Test, please obey the following to minimum fluid temperature of flow tube’s specification.
  • Page 13 8. EXPLOSION PROTECTED TYPE INSTRUMENT For CSA E79 Series HAZARDOUS LOCATIONS Conduit Sealing Fitting Flameproof for Zone 1, Ex dme [ia] IIC T6...T3 Magnetic Flowmeter Intrinsically safe (electrodes), Ex ia IIC T6...T3 Electrode Circuit Um: 250 Vac/dc Maximum power supply voltage: 250 Vac/130 Vdc Excitation Circuit: 140V max Enclosure: IP66, IP67 18"...

Table of Contents