installed and grounded in accordance with all local
codes and ordinances.
Do not modify the plug provided - if it will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface
that is green with or without yellow stripes is the
equipment-grounding
conductor.
replacement of the electric cord or plug is
necessary, do not connect the equipment-grounding
conductor to a live terminal.
Check
electrician or service personnel if the grounding
instructions are not completely understood, or if
in doubt as to whether the tool is properly
grounded. Failure to comply may cause serious
or fatal injury.
Use only 3-wire extension cords that have 3-prong
grounding plugs and 3-pole receptacles that accept
the tool's plug.
Repair
or
replace
damaged
immediately.
115 Volt operation only
This tool is intended for use on a circuit that has an
outlet that looks like the one illustrated in A, Figure
8. An adapter, shown in B and C, may be used to
connect this plug to a 2-pole receptacle as shown in
B if a properly grounded outlet is not available. The
temporary adapter should be used only until a
properly grounded outlet can be installed by a
qualified electrician. This adapter is not permitted in
Canada. The green-colored rigid ear, lug, and the
like, extending from the adapter must be connected
to a permanent ground such as a properly grounded
outlet box.
Figure 8

8.2 Extension cords

Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one
heavy enough to carry the current your machine will
draw. An undersized cord will cause a drop in the
line voltage resulting in power loss and overheating.
The table below shows the correct size to use
depending on the cord length and nameplate
If
repair
or
with
a
qualified
or worn cord
ampere rating. If in doubt, use the next heavier
gauge. Remember, the smaller the gauge number,
the heavier the cord.
Power
Current
Line
(Amps)
voltage
0-6
120
6-10
120
10-12
120
12-16
120
Extension Cord Recommendations

9.0 Adjustments

Unplug machine from power
source
before
adjustments. Failure to comply may cause
serious injury.

9.1 Tilting table

Refer to Figure 8:
1. Loosen lock knob (A).
2. Tilt table up to 45 degrees to the right or down
5 degrees to the left. The angle can be read on
the scale (B) on the trunnion bracket.
Note: Table perpendicular (90º) to the blade
corresponds to a scale indication of 0º.
3. Tighten lock knob (A).
Note: The table stop (C) must be adjusted to permit
the table to tilt to the left.
9
Extension Cord
Cord length
Cord gauge
in feet
(AWG)
0 to 25
18
25 to 50
16
50 to 100
16
over 100
14
0 to 25
18
25 to 50
16
50 to 100
14
over 100
12
0 to 25
16
25 to 50
16
50 to 100
14
over 100
12
0 to 25
14
25 to 50
12
over 50
not
recommended
Table 1