8. Power Adjustment
Power Adjustment - Adjusting to standard power voltages, which are written in
O
the upper right side of PDP module. These values were already adjusted by PDP
module makers while producing. Therefore, if there are some problems in picture
after adjusting, you should classify that PDP module as a fault and contact to PDP
module maker.
Input Video Pattern - 100 IRE Full White Pattern
O
8-1. Vs(Sustain Voltage) : Discharge Sustain Voltage
Measurement Equipment : Digital Volt Meter(DC volt mode)
O
Adjusting TP : Vs TP
O
Adjusting Location : RV 401
O
Optimum Adjusting Voltage : The voltage which is written in the label located in
O
upper right side of the PDP module.(Typical Voltage : 184V)
Voltage Adjustment Label
-36-