INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

3
Batteries
2
Wireless remote control
Remark :
• Detail of accessory and installation
parts can see in the accessory sheet.
• Some pictures might be di erent from
the actual parts.

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
Liquid side :
6.35 mm
Gas side
:
12.70 mm
A
(RAS-18BKS)
15.88 mm
(RAS-24BKS)
Pipe insulating material
B
(polyethylene foam, 8 mm thick)
C
Putty, PVC tapes
1115551271_(01_EN).indb 2
6
Flat head
4
Remote control holder
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be exposed
to a strong wind.
Q'ty
• Use
8 mm or
One
each
1
One
each
2
For the rear left and left piping
Hook
1
Installation
plate
Insert the cushion between the
indoor unit and wall, and tilt the
indoor unit for better operation.
Do not allow the drain hose to get
slack.
Shield pipe
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Right
Rear right
Bottom right
Saddle
Insulate the refrigerant pipes
separately with insulation, not
together.
Extension
drain hose
(Not available,
provided by installer)
8 mm thick heat resisting
polyethylene foam
10 mm anchor bolts and nuts.
108 mm
125 mm
28 mm
Air inlet
Air outlet
90 mm
600 mm
Drain outlet
Wall
Cut the piping
hole sloped
slightly.
Rear
Left
left
Bottom left
12/17/15 3:30 PM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-24bas seriesRas-18bas seriesRas-24bks series