Table of Contents

Advertisement

SAGEM Défense Sécurité
TM
M
A
ORPHO
CCESS
Installation Guide
TM
MorphoAccess
200/220/300
July 2006

Advertisement

Table of Contents
loading

Summary of Contents for Sagem MORPHOACCESS 200

  • Page 1 SAGEM Défense Sécurité ORPHO CCESS Installation Guide MorphoAccess 200/220/300 July 2006...
  • Page 2 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 3: Table Of Contents

    IEGAND INPUT WIRING LOCK OUTPUT WIRING LOCK INPUT WIRING UTPUT RELAYS AND AMPER SWITCHES WIEGAND / DATACLOCK: MOTHERBOARD CONFIGURATION USER INTERFACE ACCESS CONTROL BY IDENTIFICATION (MORPHOACCESS™ 200) ACCESS CONTROL BY IDENTIFICATION (MORPHOACCESS™ 300) SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 4 ACCESS THE SET UP FUNCTIONS OF THE SYSTEM CONFIGURATION MENU HOW TO EDIT PARAMETERS? NETWORK PARAMETERS EXAMPLE SYSTEM AND ADMIN PASSWORDS ™ S ORPHO CCESS YSTEM DMINISTRATOR ™ A ORPHO CCESS DMINISTRATOR SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 5 SIGNALS : LED IN IEGAND ATACLOCK SIGNAL ETTING UP IEGAND NTERFACE ID SENDING ON UDP ID SENDING ON RS232 OR RS422 « COM1 » SENDING ON « COM2 » SENDING ON SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 6 ADMIN CARD FORMAT (MORPHOACCESS 220 ONLY) SAGEM KEYS APPING COMMUNICATION PROTOCOL MORPHOACCESS TECHNICAL CHARACTERISTICS ISPLAY EYBOARD EMORY ERIPHERALS INTERFACES OWER SUPPLY IZE AND WEIGHT NVIRONMENTAL CONDITIONS TORAGE CONDITIONS LEANING PRECAUTIONS RECOMMENDATIONS SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 7 APPENDIX 3 - ISO 7811/2-1995 - TRACK 2 DATACLOCK FORMAT ATA ENCODING TABLE ATACLOCK LEVELS APPENDIX 4 - RESERVED CONFIGURATION APPENDIX 5 - FINGERPRINT PLACEMENT RULES APPENDIX 6 – RECOGNITION MODES BIBLIOGRAPHY DRILLING TEMPLATE SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 8 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 9: Introduction

    To ensure the most effective use of your SAGEM MorphoAccess™, we recommend that you read this Installation Guide totally. The SAGEM logo and trademark are the property of SAGEM Défense Sécurité. All other trademarks or product names are trademarks or product names of the respective title holders.
  • Page 10: Safety Instructions

    Ground only if the MorphoAccess™ was before connected and tested in working. Europe : SAGEM hereby declares that the SAGEM MorphoAccess™ has been tested and found compliant with the below listed standards as required by the EMC Directive 89/336/EEC: EN55022 (1994)/EN55024 (1998) and by the low voltage Directive 73/23/EEC amended by 93/68/EEC: EN60950 (2000).
  • Page 11: Replacement Of The Battery Located On The Motherboard

    Remplacer uniquement avec une batterie du même type ou d’un type équivalent recommandé par le constructeur. Éliminer de façon appropriée. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 12: General Description

    Sensor Display 136 x 34 dots MIFARE Card reader Function keys (MA220 only) Keyboard Mounting keyholes Anti-theft entry Cable entry Metal chassis SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 13: Installation Procedure

    Drill the hole for the third screw in the centre of the slot so that it is possible to correct the position later, if necessary. c) The mounting screws must be 5 mm diameter maximum. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 14: Stage 2: Mounting The Metal Chassis Assembly

    Hold the chassis in place with a screw through the mounting slot. e) Adjust the position, and fix in place by tightening all three screws. f) Connect cables to terminal blocks (see the detailed instructions in the following sections). SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 15: Stage 3: Connecting The Chassis Assembly To The Cover Assembly

    Position of the ribbon cable as the case is closed Cover assembly The ribbon cable must be folded as shown so that the case closes easily without damaging the cable Chassis assembly SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 16: Stage 4: Closing Morpho Access

    The cover is fitted onto the chassis by rotating it. M4x10 assembly Assembled screws. Use screwdriver TORX 20 MorphoAccess SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 17: How To Upgrade Morphoaccess™ 200 To

    This remark does not concern 13 pin card. After card flash installation, for the first terminal power on, a memory initialization is performed during approximated 1 minute, then will increase the terminal starting time. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 18: Electrical Interface

    COM1 RS422 serial interface 7 pin block Output relay and Tamper-Switch 34 way ribbon cable Cable connection to main assembly 5 pin block COM2 reduced RS232C serial Fuse 2.5 A quick blow fuse SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 19: Power Supply Cable

    Otherwise, as the unit is a peripheral, the connections must be crossed over: Rx on the MorphoAccess™ is connected to Tx on the host and Tx on the MorphoAccess™ is connected to Rx on the host. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 20: Com1 Deister Wiring ( Optional )

    AB wires to the Tx port. AB wires are connected to the Deister contactless card reader as defined in its install manual. For more information about this option, please contact your SAGEM sales representative. Terminal block J1 Pin 1...
  • Page 21: Com2 Rs232

    Terminal block J4 Pin 1 Data 0 Output Pin 2 Data 1 Output Pin 3 LEDin Input Pin 4 Ground Ground Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 22: Wiegand Input Wiring

    The supply available to the peripheral is +12 V at 250 mA max. Terminal block J4 Pin 1 Data Output Pin 2 Clock Output Pin 3 Not connected Pin 4 Ground Ground The electrical interface is 5 V TTL. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 23: Data Clock Input Wiring

    Terminal block J5 Pin 1 Data Input Pin 2 Clock Input Pin 3 Not connected Pin 4 Not connected Pin 5 Ground Ground The electrical interface is 5 V TTL compatible. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 24: Output Relays And Tamper Switches

    100 mA at 12 VDC max according to the safety extra low voltage. Anti-theft switch ratings 1 A at 30 VDC according to the safety extra low voltage requirements (42.4 VAC max, 60 VDC max) independently of the power supply. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 25: Wiegand / Dataclock: Motherboard Configuration

    SW3 must be closed SW4 must be open SW5 must be open SW6 must be closed SW7-8: Wiegand / Dataclock input (Interruptions) Open Open = Not allowed Closed Open = Wiegand mode SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 26 Open Closed = Dataclock mode Closed Closed = Not allowed SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 27: User Interface

    2 In stand alone mode, the local base is sized for 800 persons, 2 fingers. In MEMS mode, it is possible to manage up to 3000 persons in a base, 2 fingers. 3 For more information, see MorphoAccess Host System Interface Specification. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 28: Access Control By Identification (Morphoaccess™ 200)

    Once the person's identification is done, the terminal automatically loops back and waits for a new finger. This display remains for about 4 seconds. 4 Port used to exchange ID is Wiegand/Dataclock or COM1/COM2 or Ethernet. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 29: Access Control By Identification (Morphoaccess™ 300)

    Place your finger for Identification Please Key 5 pressed : now using base 5. Base does not exist Please select Another one Key ‘#’ then ‘3’ pressed : now using base 13. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 30 Welcome 707251 IDENT. OK Once the person's identification is done, the terminal automatically loops back, selects base 0 and waits for a new finger. This display remains for about 4 seconds. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 31: Access Control By Authentication - Id Sent On Wiegand Or Dataclock

    (MorphoAccess™ 200 and 300) Authentication mode with local database /cfg/Maccess/Admin/mode This mode requires a peripheral equipment which will send the ID of the person to authenticate to the MorphoAccess™ Wiegand or Dataclock input. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 32 0 and waits for a new input ID. This display remains for about 4 seconds. When using this feature with Wiegand input, ID should be a value between 0 and 65535. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 33: Contactless Authentication Without Database

    To configure the MorphoAccess in this mode, use Asystem and edit /cfg/Maccess/Admin/mode, then enter 3. This mode divides into several sub modes. If the authentication (or the PIN control) fails a second attempt is possible without representing the card. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 34: Id Only Mode

    Smart Card So that MorphoAccess triggers the access or returns the user ID to the central security controller, user should just present his MIFARE card to the terminal. Welcome 92745 AUTHENT. OK SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 35: Templates Or Biopin Code Mode

    If card contains user BIOPIN, user is invited to enter it. Please enter Biometric PIN If the authentication is successful, the terminal triggers the access or returns the user ID to the central security controller. Welcome John Smith AUTHENT. OK SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 36: Pin Code Mode

    Then, user is invited to enter his PIN code. Please enter PIN If the authentication is successful, the terminal triggers the access or returns the user ID to the central security controller. Welcome John Smith AUTHENT. OK SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 37: Pin Code Then Templates Or Biopin Code Mode

    If card contains user templates, user is invited to place his finger for biometric authentication. Place your finger For authentication Please If card contains user BIOPIN, user is invited to enter it. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 38 Please enter Biometric PIN If the authentication is successful, the terminal triggers the access or returns the user ID to the central security controller. Welcome John Smith AUTHENT. OK SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 39: Card Defined Mode

    (in addition to card value mode data) ID only Minutiae or BIOPIN ID, name, templates or BIOPIN PIN code ID, name, PIN PIN code then templates or BIOPIN name, PIN, code templates or BIOPIN SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 40: Contactless Authentication With : Standard Card

    ID on a MIFARE card, local templates (MorphoAccess 220). Contactless authentication with database /cfg/Maccess/Admin/mode Contactless authentication with database : id format /cfg/Maccess/Contactless/ID Format SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 41 (5.3 version). Authentication of 92745 Place your finger If the authentication is successful, the terminal triggers the access or returns the user ID to central security controller. Welcome 92745 AUTHENT. OK SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 42: Contactless Authentication With Database: Binary Id

    This mode is useful for using the card serial number as an identifier. Contactless authentication with database /cfg/Maccess/Admin/mode Contactless authentication with database: id format is binary /cfg/Maccess/Contactless/ID Format SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 43 ID size in bytes /cfg/Maccess/Contactless/ ID size [1-8]: ID size in bytes ID length in database is limited to 24 characters. It means that the binary ID length is limited to 8 bytes. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 44 ID is stored under “182469953390769” in the database. ID format in the database is ASCII. The record ID must be: “182469953390769” 0x31 0x38 0x32 0x34 0x36 0x39 0x39 0x35 0x33 0x33 0x39 0x30 0x37 0x36 0x39. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 45: Proxy Mode

    This mode allows controlling the MorphoAccess™ remotely using a set of biometric and databasing management function interface access commands. Proxy Mode For more information, please contact SAGEM or refer to document MorphoAccess Host System Interface Specification. MorphoAccess™ Host system SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 46: Merged Mode

    (operation identical to contactless authentication without database mode). If there is no database, user is warned but MIFARE card presentation is still possible. Please place your finger or Present card Base does not exist Please Present card SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 47: Authentication Mode With Database: Using Keyboard Id

    Once the ID is entered, the user confirms with F4 button. Place your finger For authentication Please If the user doesn’t valid its ID after a 20 seconds timeout the ID is erased of the screen. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 48: Software Administrator Interface

    MorphoAccess Host System Interface Specification. Result (OK – NOK) Administration: • • TCP IP • RS232 / RS422 • RS232 / RS422 • Wiegand / Dataclock SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 49: Biometric Management Operations

    Administrator field. In order to access the Control menu, the Administrator's fingerprint template or pin code must be entered. To enter the pin code, select the N menu. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 50: System (Mms)

    1. This operation creates a database with ID 0. This database can contain 800 records with two biometric data fields, an ID field and an Administrator field. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 51: Insert Template /Id In Database

    “simple” user or an administrator. (MorphoAccess™ 200 only) To remove a single template/ID record from the database, select the menu. You will then have to enter the ID of the person and validate it. If SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 52: Remove All Template /Id From Database

    MA220 restart as a MA200. Then the original value of the key (usually “2”), must be restore manually and the MA restarted to be again a MA220. In order to update the modified parameters, it is necessary to reset the MorphoAccess™ terminal. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 53 E key select the In the main menu of the administrator mode, with T key. /cfg/Maccess parameters are updated immediately, and reboot action is unnecessary. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 54: Access The Set Up Functions Of The System

    G menu allows you to set up network and specify additional parameters. N item allows you to browse for software modules present in your SAGEM MorphoAccess™ and see their revision number(s). B item displays the terminal serial number, MicroBoot revision and Ethernet physical address of your machine.
  • Page 55 SYSTEM MENU SETTING EXIT MORE G menu allows you to set the LCD contrast and the time and date. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 56: Configuration Menu

    Address: 134.1.32.214 PREV NEXT EXIT EDIT The How to edit parameters? network parameters section page 57 explains how to edit a value. Some parameters are reserved and must not be changed. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 57: How To Edit Parameters? Network Parameters Example

    FILE : cfg/net SECTION :ip Address : 134.1.32.214 PREV NEXT EXIT EDIT You can now edit you MorphoAccess™ IP address. cfg/net Address 134.1.32.214 LEFT RIGHT CANCEL T and T keys move the cursor. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 58 The restores the previous address value. The IP subnet mask and IP default gateway are set up in the same way. Contact your network Administrator for these values. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 59: System And Admin Passwords

    ™ Administrator Pin /cfg/Maccess/Admin/PwdAdmin « 12345 » default This password restricts access to “Admin mode”. Default value is « 12345 ». FILE: cfg/Maccess SECTION: Admin Pwd: 12345 PREV NEXT EXIT EDIT SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 60: Setting Up Host Communication

    (with MEMS) but never in both modes. Configuring the key to 0 will disable MEMS connection. For more information about commands accepted by the terminal please refer to MorphoAccess™ Host System Interface. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 61: Setting Up Matching Parameters

    From the 4.4 release of MorphoAccess firmware it is now possible to filter marks left on the sensor. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 62: Setting Up Recognition Mode

    Gabor coding is disabled. The control is faster in any case (identification succeeded or not). This setting is advised for users familiarized with biometric control and in standard conditions of use. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 63 Default value is 5 seconds. When the terminal switches in "light only" mode the sensor will briefly flash. Recognition mode (light, gabor …) /cfg/Maccess/bio./ 0 Light only identification strategy 1 Light then gabor (default) SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 64: Matching Threshold

    Identification and authentication thresholds may be defined independently. Identification mode: FILE : cfg/bio SECTION :matching threshold identify: 3 PREV NEXT EXIT EDIT Authentication mode: FILE : cfg/bio SECTION : matching threshold Authenticate : 3 PREV NEXT EXIT EDIT SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 65 FAR < 0.0001% FAR < 0.00001% Very high threshold (few false FAR < 0.0000001% acceptances) Secure application High threshold for test purpose There are very few recognitions, only and many rejections SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 66: User Interface Settings

    Caution: In the MorphoAccess 5.41 the User defined language is the number 9, instead of 3 in anterior versions. Language selection A user may choose his language by pressing a button. The language choice is circular. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 67: Identification Information

    X of identified person. Welcome Field 2 0 Nothing is displayed. 1 System displays ID of identified person. X System displays data present in additional field number X of identified person. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 68: Clock

    Pressing a key wakes the MorphoAccess™ up. Idle mode settings /cfg/Maccess/G.U.I./idle timer in min 0 MorphoAccess never enters idle mode. n MorphoAccess™ enters idle mode after n minutes. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 69: Display Personalization

    File selection /cfg/Maccess/BMP mode / file 0 picto0.bin (default) 1 picto1.bin 2 picto2.bin. Note: see the document MorphoAccess Screen Customization Guide V2.0.pdf to know the modifications of the Bitmap tool SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 70: Setting Up Contactless Reader Parameters

    Blocks are numbered in an absolute way, 1 for block 0 sector 0, then 3 blocks for each sector. SAGEM biometric data (ID, name and templates) are located on the card thanks to a BNC address where: • <B> is the first block number to read, •...
  • Page 71 28 When templates are stored. Security key 1 MIFARE security key A then /cfg/Maccess/contactless/C B is selected (default) 2 MIFARE security key A is selected. 3 MIFARE security key B is selected. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 72: Log File

    1 MorphoAccess is logging its activities. It is possible to download the diary file. For more information on this feature, refer to the MorphoAccess Host System Interface Specifications. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 73: Setting Up Time Mask

    MorphoAccess Host System Interface Specifications. Time mask activation /cfg/Maccess/Admin/Time mask 0 Time mask feature is disable (default). 1 Time mask feature enabled. Users must be on time to have their access granted.. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 74: Setting Up Download Agent - (Sdl)

    Password to present in order to connect the agent (8 digits) /cfg/sdl/Download/Password « 12345678 » (default) Remark: the password must contain exactly 8 digits. Number of failed attempts before deactivating the agent. /cfg/sdl/Download/Ratif 3 (default) SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 75: Wiegand / Dataclock Configuration

    Please refer to MorphoAccess Remote Messages Specifications for more information about this functionality. Sending ID Wiegand or Dataclcock /cfg/Maccess/Wiegand/dataclock/ send 0 ID is not sent (default) 1 ID is sent SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 76: Wiegand / Dataclock : Advanced Informations

    0 and 4294967295, depending on Wiegand data format (see section APPENDIX 2 - WIEGAND DATA FORMAT page 107). Installation Code (« facility code ») /cfg/Maccess/Wiegand/dataclock/ Facility code 7 (default) [0 4294967295] SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 77: Wiegand : Facility Code Verification

    Signal LED OUT – Card Present /cfg/Maccess/Wiegand/dataclock/ led out/card present Autodetect The led out signal can behave as a card present signal depending on the hardware configuration of the system: DataClock IN/ DataClock OUT: Card present SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 78 Wiegand IN/ DataClock OUT: card present (priority goes to dataclock out) Wiegand IN/ Wiegand OUT: led out DataClock IN/ Wiegand OUT: inactive. Force Led out The led out signal only behaves as a led out signal. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 79: Wiegand / Dataclock : Led In Signal

    When the ACS validates the control a timeout must be specified. ACK timeout /cfg/Maccess/Wiegand/dataclock/ Timeout Time seconds during which MorphoAccess™ will wait acknowledgement signal from the ACS through Led in signals. (“Led IN 2“ mode). SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 80: S W I

    Start Defines the start control bit. Reset to 0. Set to 1. Even parity calculated over the n first bits. Odd parity calculated over the n first bits. No start bit SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 81 Custom Reserved for SAGEM custom protocols. Note: The number of bits of the Wiegand ID is limited to 64 bits Examples : See APPENDIX 2 - WIEGAND DATA FORMAT page 107. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 82: Id Sending On Udp

    Please refer to MorphoAccess Remote Messages Specifications for more information about this functionality. ID sending on UDP /cfg/Maccess/Ethernet/ Send Not activated L’ID is sent on UDP « aaa.bbb.ccc.ddd » central security controller. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 83 1 L’ID is sent in Hexa. 2 L’ID is sent in BCD « » « » Activation Sending ID on COM2 /cfg/Maccess/COM2/Send 2 Nothing is sent (default) 3 L’ID is sent on COM2 SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 84 COM2 parameters are defined by cfg/ser1. Identifier format (COM2) ID format (COM2) /cfg/Maccess/COM2/Format 0 L’ID is sent in ASCII. 1 L’ID is sent in Hexa. 2 L’ID is sent in BCD SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 85: Serial Port Parameters

    9600 bps (default) 19200 bps 28800 bps 38400 bps 57600 bps 115200 bps Data bits /cfg/ser0/parameters/ databits 5 databits 6 databits 7 databits (default) 8 databits Parity /cfg/ser0/parameters/ parity Even (default) SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 86: U Dcom1

    To connect a Deister reader on COM1 the serial link parameters must have the following values : DEISTER reader utilization /cfg/ser0/parameters/ Baudrate 9600 Databits Stopbits Parity Flow ctrl COM2 (ser1) /cfg/ser1/parameters/ Please refer to COM1 port (ser0) section SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 87: Relay Activation

    A relay may be activated . Relay parameters /cfg/Maccess/Relay Active 0 (default value) Relay not active 1 reserved 2 Relay active Time in 100 ms [10 –200], 30 by default. Relay aperture time in 100 ms. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 88: Time And Attendance

    After 10 seconds of inactivity on identification mode(no finger detected on the sensor), the terminal switches back to the selection screen. In this case the operation result is logged and/or sent to the controller (time-out). SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 89 IN, IN (from) DUTY, OUT (on) DUTY and OUT. display Keys label are in English. Keys label are in Spanish. Keys label are in French. Switches to graphic mode (default value). SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 90 For more information about log configuration and retrieving, refer to the MorphoAccess Host System Interface Specifications. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 91: The Version Menu

    N key to access the From the System Menu, press the information file. This display contains information that may be necessary if the SAGEM MorphoAccess™ requires technical support. It should not normally be necessary to access this display unless requested by SAGEM technical support personnel.
  • Page 92: The Serial Number Menu

    From the System Menu, press the SER NB key to display the serial number. Serial # is your SAGEM MorphoAccess™'s serial number. MicroBoot revision revision number your SAGEM MorphoAccess™'s MicroBoot. This revision number may be needed when requesting technical support.
  • Page 93: The Setting Menu

    S key decreases the contrast. CONTRAST SETTINGS CONTRAST VALUE : 5 LESS MORE EXIT C menu allows you to set the current date and time. RTC SETTINGS Time 16:45:44 Date 14/06/00 SETTIME SETDATE EXIT SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 94 L key aborts editing and returns to the previous menu. DATE SETTINGS DATE (DDMMYY) : 100600 VALID CANCEL NB : You can use the correction key # to delete the last characters entered. Note section Recommendations page 104about date synchronisation. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 95: Access The Mifare Keys Update Menu (Morphoaccess 220)

    Then the MorphoAccess™ comes back to the administrator menu after 2 seconds. If for some reasons the update is not successful (power shutdown before the end of the operation for instance), a new hotkey will be available the SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 96 MIFARE KEYS UPDATE Please Present Admin Card <Curr ent Keys : INVALID> PREV LOAD DFLT KEYS S hotkey will allow you to re-update the Pressing the 32 keys with the default value 0xFFFFFF. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 97: Contactless Card Data Structure (Morphoaccess 220 Only)

    This tag contains the name of the cardholder. This name will be displayed on a positive authentication. This tag holds a length fixed string. Data are then padded with null characters. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 98 This tag contains the user BIOPIN code (used instead of the user minutiae). CARD MODE Tag Data type Size Tag (Hexa) Card mode 0x35 This tag contains the authentication method to use. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 99: Admin Card Format (Morphoaccess 220 Only)

    The keys are 6 bytes long. There are 32 keys to initialize, representing 192 data bytes. Mifare 4K card Data Size Tag (Hexa) SAGEM keys 0x03 The keys are 6 bytes long. There are 80 keys to initialize, representing 480 data bytes. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 100: Mapping

    Mapping is the same than with 1K cards. There are 80 keys instead of 32: 31 blocks will be required on the card (483/16). 13 bytes will be left empty in the last used block. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 101: Communication Protocol

    Identifier Length Data (DLE data bytes are stuffed) <CRC> Transmission error control Depends on the frame <DLE> 0x1B <ETX> End Text 0x03 For more information, refer to document MorphoAccess Host System Interface Specifications. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 102: Morphoaccess Technical Characteristics

    Wiegand or Dataclock ISO2 input. Relay. Tamper switch. Antitheft switch. 12 V ± 5% power supply Cable cross section depends on the length 0. mm2 recommended. SAGEM recommends to use MorphoAccess™ Supply ref 251411986. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 103: Size And Weight

    UV Storage conditions Avoid exposure to UV - Temperature - 20°C to 70°C. - Humidity < 95%. A dry cloth should be used. Acid liquids or alcohol , abrasive materials are forbidden. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 104: Recommendations

    It is strongly recommended that you do not install your SAGEM MorphoAccess™ in the vicinity of gas stations, petroleum processing facilities or any other facility containing flammable or combustible gasses or materials. • Do not attempt to repair your SAGEM MorphoAccess™ yourself. The manufacturer cannot be held responsible for any damage/accident that may result from attempts to repair components.
  • Page 105: Date / Time Synchronisation

    The terminal clock has a 40 10 ppm time deviation. manufacturer cannot held responsible above recommendations are not followed or if the SAGEM MorphoAccess™ is incorrectly used. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 106: Appendix 1 - Ethernet Color Standard

    White blue White blue Yellow RX(-) Receive Green Orange Blue Data Minus (Input) No connection White Brown White Brown Purple No connection Brown Brown Brown Compliant with 10 base T IEEE Specification. SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 107: Appendix 2 - Wiegand Data Format

    12 code bits. Even parity Facility code Data Odd parity (1 bit) (8 bits) (16 bits) (1 bit) Compliant with access control 26-Bit - Wiegand reader interface standard 03/1995. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 108: Examples

    /Start: 2.18 //even parity calculated over the first 18 bits /Site: 0.0 /ID: 1.35 //35-bit ID (max value is 4294967295) /Custom: /Stop: 3.18 //odd parity calculated over the last 18 bits SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 109: Appendix 3 - Iso 7811/2-1995 - Track 2 Dataclock Format

    The least significant bit of every digit is sent first; the fifth bit is an odd parity bit for each group of 4 data bits. The complete message always looks as follows: data left edge start right edge characters SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 110 The fifth bit is the odd parity of the 4 LRC bits (it is not calculated over all the parity bits). Input data should be preceded and followed by a clock synchronization pattern (NULL data). SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 111: Dataclock Levels

    In normal operation mode (default) input and output signals are defined Other modes are (only for output): SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 112: Appendix 4 - Reserved Configuration

    For proper operation, this settings should not be changed. /cfg/lcd0/display/type: 1 /cfg/lcd0/contrast/value: 0 /cfg/serx/mode/connection: EXT /cfg/serx/mode/mode: 450 db/seq flash/start: 0 /cfg/bio/video/channel: 0 /cfg/bio/video/rotation: 0 /cfg/lic/licences/* /cfg/bio/base n/timestamp: 0 /cfg/Maccess/bio/segment gabor:1 /cfg/Maccess/contactless/keys status/* /admin/security/* /cfg/Maccess/language/version : 1 if version 5.41 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 113: Appendix 5 - Fingerprint Placement Rules

    To ensure a good quality contact of your finger on the terminal you must leave your finger on the sensor until sensor light is turned off. Area containing most of the information Fingerprint Placement Fingerprint Orientation Fingerprint Inclination Fingerprint Rotation SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 114: Appendix 6 - Recognition Modes

    (*): Mode 3 and 5 allows defining the control steps with this key: /cfg/Maccess/Contactless/without DB mode 0, 1, 2, 16, 18 Mode Description Card mode ID “only”, no biometric verification Biometric verification or BIOPIN PIN code PIN code then biometric verification or BIOPIN SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 115: Bibliography

    Explain how to create personalized screen. Database Manager User Guide 1.0 This tool allows saving / restore local databases. Use Ethernet link. Easy Downloader User Guide 1.1 This software is designated to update MorphoAccessTM firmware. SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 116: Drilling Template

    SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. SK-0000011145-05...
  • Page 117 SK-0000011145-05 SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
  • Page 118 SAGEM Défense Sécurité Siège social : Le Ponant de Paris 27, rue Leblanc - 75512 PARIS CEDEX 15 - FRANCE Société anonyme à directoire et conseil de surveillance au capital de 36 405 229 € 562 082 909 RCS PARIS...

This manual is also suitable for:

Morphoaccess 220Morphoaccess 300

Table of Contents