Kestrel 800.784.4221 Instruction Manual page 13

Table of Contents

Advertisement

Gun lIBRARy & InFORMATIOn sCREEn
MV-Temp Table
This allows you to enter and maintain a table of muzzle
velocities based on temperature. If an entry is input
into the table, the muzzle velocity is applied at all
temperatures (this means that the value is then locked
and cannot be altered by using
information screen). If two or more entries are input into
the table, the Kestrel uses the linear interpolation and
the temperature sensor to determine the appropriate
muzzle velocity. (Note: this value will only change if
the temperature changes and you exit and re-enter
the gun information screen; once a muzzle velocity
value is entered for a particular temperature, you can
not make another muzzle velocity value for the same
temperature.)
• To access MV-Temp table, scroll to MV (Muzzle
Velocity) to highlight it and press
to scroll to MV-Temp and press
• Press
Muzzle velocity
highlighted to enter the Table
MV
2900
f
s
p
Item screen.
feet
er sec
• Use
p
MV-Tem
"Temp" and "MV. " Use
p
to adjust each value.
• To clear a Table Item, scroll
down to Clear and
press
Table item
• Press
10ºF
Tem
p
Gun Information
2900
MV
f
s
p
screen.
Clear
and
on the gun
, then use
to enter.
while "New entry" is
or
to scroll to
and
.
to exit to return to the
Gun InFORMATIOn sCREEn (COnT.)
Drag Curves
The Kestrel with Applied Ballistics allows you to use G1 or
G7 drag curve model, or AB's custom drag curves.
• To select the appropriate drag curve, scroll to "DC."
• Use
and
to scroll through options.
• If a custom drag curve is used, no further adjustment is
necessary. If using G1 or G7 drag curves, you must adjust
the BC by scrolling down and editing to the proper value.
For more information on the custom drag curves, please see
page 18.
Calibrate Muzzle Velocity
This allows you to calibrate your muzzle velocity based
on the actual drop of a round at a range where the bullet
is supersonic. With the range and the drop entered, the
Kestrel automatically adjusts muzzle velocity to match.
• To access the muzzle velocity Cal, scroll to Cal MV to
highlight it and press
The number shown to the top right
MV Cal
1398m
of the screen is the suggested range
Range
1275m
distance at which to calibrate
Drp
9.35mil
muzzle velocity. This range is
-Cal
calculated from when the bullet is
MV
2826fps
at a speed of Mach 1.2.
• Use
and
to adjust the range at which you are
firing. The Drop will update with the range.
• Use
to scroll to "Drp. " Use
to match the observed drop of the bullet at range.
• Use
to scroll to "Cal" and press
Calibrated Muzzle Velocity value will be displayed at the
bottom of the screen.
• Press
to exit to return to the Gun Information
.
and
to adjust the value
. The Calculated
13

Advertisement

Table of Contents
loading

Table of Contents