  • Page 1 WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER MODEL#: ARC-14SH Instruction Manual Congratulations on your new WHYNTER product. To ensure proper operation, please read this Instruction Manual carefully before using this product. Keep this manual in a safe place for future reference.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION SAFETY PRECAUTIONS IDENTIFICATION OF ACCESSORIES IDENTIFICATION OF PARTS OPERATING YOUR AIR CONDITIONER INSTALLATION INSTRUCTIONS 9-10 AIR FILTERS INSTALLATION OPERATION INSTRUCTIONS 12-13 WATER DRAINAGE REMOTE CONTROL CARE AND MAINTENANCE TECHNICAL DATA TROUBLESHOOTING 18-19 WARRANTY INFORMATION P a g e...
  • Page 3: Introduction

    We trust that your Whynter air conditioner will provide the performance and reliability that we stand for.
  • Page 4: Safety Precautions

    Your safety and the safety of others are very important to us. To reduce the risk of fire, electrical shock or injury when using your appliance, follow these basic precautions. SAFETY PRECAUTIONS Before the portable air conditioner is used, it must be properly positioned and installed as detailed in this manual.
  • Page 5: Operating Condition

     Keep fingers out of the air intakes and air outlets.  The unit is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet conditions.
  • Page 6: Identification Of Accessories

    IDENTIFICATION OF ACCESSORIES Note: Please visit whynter.com for optional accessories information IMAGE ACCESSORY NAME QUANTITY Intake and Exhaust hose 2 pieces Fixture 2 pieces Screws 8 pieces Hose connectors 4 pieces 1 set Window slider kit Cover 2 pieces Remote control...
  • Page 7: Identification Of Parts

    IDENTIFICATION OF PARTS Front 1. Air vent 2. Control panel Rear 3. Evaporator air intake / air filter 4. Air intake hose 5. Air exhaust hose 6. Casters 7. Drain plug 8. Power cord P a g e...
  • Page 8: Operating Your Air Conditioner

    OPERATING YOUR AIR CONDITIONER Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of the functions. Follow the symbol for the desired function. The unit can be controlled by the unit control panel alone or with the remote control. CONTROL PANEL Timer Power Control...
  • Page 9: Installation Instructions

    We do not recommend extending the hose more than 9' long. If you are interested in purchasing an additional 5’ exhaust hose, please contact support@whynter.com for retail sales information or visit whynter.com for a list of optional accessories. P a g e...
  • Page 10 Window kit Installation The window kit has been designed to fit most standard vertical and horizontal windows. However, it may be necessary to modify the installation procedures to accommodate your window. NOTE: • If your window opening is smaller than the minimum length of the window slider kit, the window slider kit can be cut to fit the window opening.
  • Page 11: Air Filters Installation

    AIR FILTERS INSTALLATION Your Whynter portable air conditioner is equipped with a washable Pre-Filter and an Activated Carbon Filter. The washable Pre-Filter removes large particles such as dust, pet hair and dander. The Activated Carbon filter is designed to remove smoke and other odors. It is recommended you replace the Activated Carbon filter every 2-3 months or as needed.
  • Page 12: Operation Instructions

    OPERATION INSTRUCTIONS  BEFORE USING YOUR PORTABLE AIR CONDITIONER  Remove the exterior and interior packaging  Before connecting the appliance to a power source and operating, let the unit stand upright for a minimum of 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation SWITCHING ON/OFF THE AIR CONDITIONER ...
  • Page 13 HEATING MODE  In this mode, the air conditioner heats the room. To activate heating mode, press the Mode Control button until the RED indicator comes on. When the heating mode is set, the rear fan will start first, followed by the compressor then the air output fan into the room. Note: The compressor will start in approximately 3-5 minutes and it will take approximately 3-5 additional minutes for heat to blow from the front air output vent.
  • Page 14: Water Drainage

    3. Remove the drain cover and rubber plug and the condensed water will drain out automatically. 4. Once all the condensed water is drained, replace the drain rubber plug and cover into the drain firmly. Note: Please contact support@whynter.com for retail sales information or visit whynter.com for a list of optional accessories...
  • Page 15: Remote Control

    REMOTE CONTROL The portable air conditioner can be switched on by the remote control. NOTE:  Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences.  Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner.
  • Page 16: Care And Maintenance

    They are optional filters and should be replaced every 2-3 months or as needed if used.  Please contact support@whynter.com for retail sales information or visit whynter.com for a list of optional accessories WARNING! Never operate the air conditioner without the pre-filter in place CLEANING THE AIR CONDITIONER ...
  • Page 17: Technical Data

    • Clean the washable pre-filter regularly • Replace the activated carbon filter every 2-3 weeks depending on use • Vacuum any accumulated dust from around all vents TECHNICAL DATA Model ARC-14SH Cooling capacity 14,000 BTU Heating capacity 13,000 BTU Power supply...
  • Page 18: Troubleshooting

     Move the unit onto another circuit with the correct too low. voltage.  The power cord is damaged.  Contact Whynter Service Department. Only authorized personnel should replace damaged power cord or power plug.  The L.C.D.I. power plug for the ...
  • Page 19  Possible loose connection  Contact Whynter Service Department  Fan speed differences are not  The fan speed difference is not very Fan speed cannot be very noticeable noticeable when the compressor is on.
  • Page 20: Warranty Information

    Return freight is prepaid by Whynter within two months of purchase. After two months to one year, the customer will be responsible for the return freight cost to Whynter’s Service Center. Please package the product carefully in its original packaging to avoid damage in transit.