Error message
When a command or inquiry command could not be executed or failed,
an error message is returned.
Error Packet
X0 6Y 01 FF
X0 6Y 02 FF
X0 6Y 03 FF
X0 6Y 04 FF
X0 6Y 05 FF
X0 6Y 41 FF
X = 9 to F: BC-80 address + 8, Y = socket number
Socket number = 1 (normal)
Socket number
When command messages are sent to the BC-80, it is normal to send
the next command message after waiting for the completion message
or error message to return.
As the completion message or error message also has a socket number,
it indicates which command has ended.
The ACK message is not returned for these commands and inquiries,
and only the completion message of socket number 0 is returned.

7.2.3 VISCA Device Setting Command

Before starting control of the BC-80, be sure to send the Address
command and the IF_Clear command using the broadcast function.
VISCA interface command
IF_Clear
Clears the command buffers in the BC-80 and cancels the command
currently being executed.
Description
Message length error
Syntax error
Command buffer full
Command cancelled
No socket (to be cancelled)
Command not executable