Proline Promag L 400 Technical Information
Proline Promag L 400 Technical Information

Proline Promag L 400 Technical Information

Electromagnetic flowmeter
Table of Contents

Advertisement

Quick Links

TI01045D/06/EN/02.13
71218293
The flowmeter with integrated web server and a weight-optimized sensor
Application
• The electromagnetic measuring principle is unaffected by
pressure, temperature and flow profile
• Fully suitable for standard applications in the water and
wastewater industry
Device properties
• Up to 30 % less sensor weight
• Nominal diameter: DN 50 to 2400 (2 to 90")
• Maximum reduced installation length to DVGW/ISO
• Transmitter housing made of durable polycarbonate
• Same housing concept for compact/remote version
• Integrated data logger: measured values monitoring
Products

Technical Information

Proline Promag L 400
Electromagnetic flowmeter
Solutions
Your benefits
• Reduced installation costs – flexible mounting by one-of-a-
kind lap-joint flange concept (DN < 350/14")
• Energy-saving flow measurement – no pressure loss due to
cross-section constriction
• Maintenance-free – no moving parts
• Safe operation – no need to open the device due to display
with touch control, background lighting
• Time-saving local operation without additional software and
hardware – integrated web server
• Integrated verification – Heartbeat Technology™
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Promag L 400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Proline Promag L 400

  • Page 1: Technical Information

    Products Solutions Services TI01045D/06/EN/02.13 71218293 Technical Information Proline Promag L 400 Electromagnetic flowmeter The flowmeter with integrated web server and a weight-optimized sensor Application Your benefits • The electromagnetic measuring principle is unaffected by • Reduced installation costs – flexible mounting by one-of-a- pressure, temperature and flow profile kind lap-joint flange concept (DN <...
  • Page 2: Table Of Contents

    Proline Promag L 400 Table of contents Document information ..... . . 3 Electromagnetic compatibility (EMC) ....
  • Page 3: Document Information

    Proline Promag L 400 Document information Symbols used Electrical symbols Symbol Meaning Direct current A terminal to which DC voltage is applied or through which direct current flows. A0011197 Alternating current A terminal to which alternating voltage is applied or through which alternating current flows.
  • Page 4: Function And System Design

    Proline Promag L 400 Symbol Meaning Hazardous area Indicates a hazardous area. A0011187 Safe area (non-hazardous area) Indicates a non-hazardous area. A0011188 Function and system design Measuring principle Following Faraday' s law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field.
  • Page 5: Measuring System

    Proline Promag L 400 Measuring system The device consists of a transmitter and a sensor. Two device versions are available: • Compact version - the transmitter and sensor form a mechanical unit. • Remote version – the transmitter and sensor are mounted separately from one another.
  • Page 6: Input

    Proline Promag L 400 Input Measured variable Direct measured variables • Volume flow (proportional to induced voltage) • Electrical conductivity Calculated measured variables Mass flow Measuring range Typically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with the specified accuracy Electrical conductivity: 5 to 10 000 µS/cm/cm...
  • Page 7 Proline Promag L 400 Nominal Recommended Factory settings diameter flow Full scale value current min./max. full scale value Pulse value Low flow cut off output (v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s) (v ~ 2.5 m/s)
  • Page 8: Operable Flow Range

    Proline Promag L 400 Nominal Recommended Factory settings diameter flow Full scale value current min./max. full scale value Pulse value Low flow cut off output (v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s) (v ~ 2.5 m/s)
  • Page 9 Proline Promag L 400 Damping Adjustable: 0.07 to 999 s Assignable measured • Volume flow variables • Mass flow • Flow velocity • Conductivity • Electronics temperature Pulse/frequency/switch output Function • With the order code for "Output; Input", option H: output 2 can be set as a pulse or frequency output •...
  • Page 10: Signal On Alarm

    Proline Promag L 400 EtherNet/IP Standards In accordance with IEEE 802.3 Signal on alarm Depending on the interface, failure information is displayed as follows: Current output 4-20 mA Failure mode Selectable (as per NAMUR recommendation NE 43): • Minimum value: 3.6 mA •...
  • Page 11: Low Flow Cut Off

    Proline Promag L 400 Operating tool • Via digital communication: HART protocol • Via service interface Plain text display With information on cause and remedial measures Additional information on remote operation (→  62) Web browser Plain text display With information on cause and remedial measures...
  • Page 12 Proline Promag L 400 EtherNet/IP Protocol • The CIP Networks Library Volume 1: Common Industrial Protocol • The CIP Networks Library Volume 2: EtherNet/IP Adaptation of CIP Communication type • 10Base-T • 100Base-TX Device profile Generic device (product type: 0x2B)
  • Page 13 Proline Promag L 400 Input Assembly • Current device diagnostics • Volume flow • Mass flow • Temperature • Totalizer 1 • Totalizer 2 • Totalizer 3 Configurable Input 5 ms to 10 s (factory setting: 20 ms) Exclusive Owner Multicast...
  • Page 14: Power Supply

    Proline Promag L 400 Configuration Configuration Assembly Only the most common configurations are listed below. • Software write protection • Mass flow unit • Mass unit • Volume flow unit • Volume unit • Density unit • Reference density unit •...
  • Page 15 Proline Promag L 400 Signal transmission 0-20 mA/4-20 mA HART with additional outputs and inputs Order code for Terminal numbers "Output" and Output 1 Output 2 Output 3 Input "Input" 26 (+) 27 (-) 24 (+) 25 (-) 22 (+)
  • Page 16: Pin Assignment, Device Plug

    Proline Promag L 400 EtherNet/IP signal transmission Order code for "Output" Connection via Option N EtherNet/IP connector Remote version 6 5 7 8 4 37 36 42 41 n.c. n.c. n.c. 5 7 4 37 42 41 A0020534  1...
  • Page 17: Power Consumption

    Proline Promag L 400 Power consumption Order code for Maximum "Output" Power consumption Option L 30 VA/8 W Option N 30 VA/8 W Current consumption Transmitter Order code for "Power supply" Maximum Maximum Current consumption switch-on current Option L: AC 100 to 240 V 145 mA 25 A (<...
  • Page 18 Proline Promag L 400 Connection examples Current output 4-20 mA HART 4...20 mA – A0016800  4 Connection example for 4-20 mA HART current output (active) Automation system with current input (e.g. PLC) Cable shield, observe cable specifications (→  22) Connection for HART operating devices (→...
  • Page 19: Potential Equalization

    Proline Promag L 400 EtherNet/IP A0016805  7 Connection example for EtherNet/IP Control system (e.g. PLC) Ethernet switch Observe cable specifications (→  22) Device plug Transmitter Status input A0017163  8 Connection example for status input Automation system with status output (e.g. PLC)
  • Page 20 Proline Promag L 400 Connection example in special situations Unlined and ungrounded metal pipe This connection method also applies in situations where: • The customary potential equalization is not used • Equalizing currents are present £ ³ A0016317  10...
  • Page 21: Terminals

    Proline Promag L 400 Ground cable Copper wire, at least 6 mm (0.0093 in For remote device versions, the ground terminal in the example always refers to the sensor and not to the transmitter. The ground cable and ground disks can be ordered from Endress+Hauser (→  65).
  • Page 22: Cable Specification

    Proline Promag L 400 Cable gland • For standard cable: M20 × 1.5 with cable 6 to 12 mm (0.24 to 0.47 in) • For reinforced cable: M20 × 1.5 with cable 9.5 to 16 mm (0.37 to 0.63 in) If metal cable entries are used, use a grounding plate.
  • Page 23: Performance Characteristics

    Proline Promag L 400 A0003194  13 Cable cross-section Electrode cable Coil current cable Core Core insulation Core shield Core jacket Core reinforcement Cable shield Outer jacket Reinforced connecting cable Use in the following situations: • When laying the cable directly in the ground •...
  • Page 24: Repeatability

    Proline Promag L 400 0.5 % 0.2 % 10 [m/s] 32 [ft/s] A0005531  14 Maximum measured error in % o.r. Electrical conductivity Max. measured error not specified. Accuracy of outputs o.r. = of reading; o.f.s. = of full scale value The outputs have the following base accuracy specifications.
  • Page 25 Proline Promag L 400 A0017061 To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid the following mounting locations in the pipe: • Highest point of a pipeline. • Directly upstream of a free pipe outlet in a down pipe.
  • Page 26: Orientation

    Proline Promag L 400 Do not support the weight of the sensor on the metal casing as this could damage the metal casing and the internal magnetic coils. A0016276 Orientation The direction of the arrow on the sensor nameplate helps you to install the sensor according to the flow direction (direction of medium flow through the piping).
  • Page 27: Adapters

    Proline Promag L 400 Observe the following inlet and outlet runs to comply with accuracy specifications: • Inlet run ≥ 5 × DN • Outlet run ≥ 2 × DN 5 × DN ³ 2 × DN ³ A0016275 Adapters Suitable adapters to DIN EN 545 (double-flange reducers) can be used to install the sensor in larger- diameter pipes.
  • Page 28: Installing The Wall-Mount Housing

    Proline Promag L 400 [µS/cm] L max L max [ft] A0016539  17 Permitted length of connecting cable for remote version = permitted range Area shaded gray = length of connecting cable in [m] ([ft]) = fluid conductivity [µS/cm] Installing the wall-mount...
  • Page 29: Special Mounting Instructions

    Proline Promag L 400 Pipe mounting ø TX 25 20…70 ø ( 0.79…2.75) SW 8 A0020705 A separate mounting kit can be ordered from Endress+Hauser for pipe mounting (→  65). Special mounting Display protection instructions To ensure that the optional display protection can be easily opened, maintain the following minimum head clearance: 350 mm (13.8 in)
  • Page 30: Atmosphere

    Proline Promag L 400 • Protect the measuring device against direct sunlight during storage in order to avoid unacceptably high surface temperatures. • Select a storage location where moisture cannot collect in the measuring device as fungus or bacteria infestation can damage the liner.
  • Page 31 Proline Promag L 400 Flange connection according to EN 1092-1 (DIN 2501) [psi] [bar] PN 16 PN 10 20 40 60 80 100 120 140 [°C] -60 -40 -20 0 [°F] A0021399-EN  18 Lap joint flange PN 10/16, materials 1.4306 (304L) and 1.4307 (304L), DN 50 to 300 (2 to 12")
  • Page 32 Proline Promag L 400 Flange connection according to ASME B16.5 [psi] [bar] DN 50…250 (2"…10") DN 300 (12") [°C] -20 0 20 40 60 80 100 120 140 300 [°F] A0021403-EN  21 Lap joint flange Class 150, material A105, DN 50 to 300 (2 to 12") Flange connection according to ASME B16.5...
  • Page 33: Pressure Tightness

    Proline Promag L 400 Flange connection according to AWWA C207 [psi] [bar] -40 -20 0 20 40 60 80 100 120 140 [°C] [°F] A0021406-EN  24 Fixed flange Class D, materials 1.0044 (S275JR), 1.0425 (316L) (P265GH), A105 and A181, DN 1200 to 2200 (48 to 90")
  • Page 34: Flow Limit

    Proline Promag L 400 Nominal diameter Limit values for absolute pressure in [mbar] ([psi]) for fluid temperatures: [mm] [in] +25 °C (+77 °F) +90 °C (+194 °F) 200 (2.9) 290 (4.2) 330 (4.8) 400 (5.8) 400 (5.8) 500 (7.3) Flow limit The diameter of the pipe and the flow rate determine the nominal diameter of the sensor.
  • Page 35: Mechanical Construction

    Proline Promag L 400 Mechanical construction Design, dimensions Compact version Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, coated aluminum" with DN 50 to 300 (2 to 12") A0020352 Dimensions in SI units [mm] [mm] [mm]...
  • Page 36 Proline Promag L 400 [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] 7.60 4.06 3.54 6.57 13.3 8.07 21.3 15.8 6.54 17.7 7.60 4.06 3.54 6.57 14.3 9.06 23.3 18.1 6.54 19.7 The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.
  • Page 37 Proline Promag L 400 [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] 7.83 4.69 3.15 6.57 14.1 7.09 21.1 12.8 6.14 13.8 7.83 4.69 3.15 6.57 15.0 8.07 23.1 15.8 6.54 17.7 7.83 4.69 3.15 6.57 16.0 9.06...
  • Page 38 Proline Promag L 400 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1500 1053 1147 1500 1600 1053 1147 1600 1650 1104 1284 1650 1800 1161 1379 1800 2000 1272 1569 2000 2150 1372 1711 2150 2200 1372 1711 2200...
  • Page 39 Proline Promag L 400 Dimensions in US units [in] [in] [in] [in] [in] [in] [in] [in] 7.60 4.06 3.54 6.57 15.2 11.4 21.6 7.60 4.06 3.54 6.57 16.2 11.4 23.6 7.60 4.06 3.54 6.57 16.2 11.4 23.6 7.60 4.06 3.54 6.57...
  • Page 40 Proline Promag L 400 Dimension F Dimension G EN (DIN) ASME EN (DIN) ASME PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] –...
  • Page 41 Proline Promag L 400 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1200 1200 1350 1008 1350 1400 1008 1400 1500 1098 1147 1500 1600 1098 1147 1600 1650 1149 1284 1650 1800 1206 1379 1800 2000 1317 1569 2000...
  • Page 42 Proline Promag L 400 Dimensions in US units [in] [in] [in] [in] [in] [in] [in] [in] 7.83 4.69 3.15 6.57 17.0 11.4 21.6 7.83 4.69 3.15 6.57 18.0 11.4 23.6 7.83 4.69 3.15 6.57 18.0 11.4 23.6 7.83 4.69 3.15 6.57...
  • Page 43 Proline Promag L 400 Dimension F Dimension G EN (DIN) ASME EN (DIN) ASME PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] –...
  • Page 44 Proline Promag L 400 Dimensions in US units [in] [in] [in] [in] [in] [in] [in] [in] 6.57 0.94 7.36 0.83 9.13 3.15 1.97 Sensor remote version DN 50 to 300 (2 to 12") A0017282 Dimensions in SI units [mm] [mm]...
  • Page 45 Proline Promag L 400 [in] [in] [in] [in] [in] [in] [in] [in] 5.35 12.7 8.07 20.8 15.8 6.14 17.7 5.35 13.7 9.06 22.8 18.1 6.54 19.7 The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.
  • Page 46 Proline Promag L 400 [mm] [mm] [mm] [mm] [mm] 1800 1133 1379 1800 2000 1244 1569 2000 2150 1344 1711 2150 2200 1344 1711 2200 2300 1449 1859 2300 2400 1449 1859 2400 Dimension C Dimension D EN (DIN) ASME...
  • Page 47 Proline Promag L 400 [in] [in] [in] [in] [in] 5.35 15.1 11.4 23.6 5.35 16.2 11.4 23.6 5.35 17.2 11.4 23.6 5.35 18.8 11.4 23.6 5.35 21.6 16.7 27.6 5.35 23.0 17.9 29.5 5.35 23.6 19.7 31.5 5.35 25.6 22.8 35.4...
  • Page 48 Proline Promag L 400 Dimension C Dimension D EN (DIN) ASME EN (DIN) ASME PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] –...
  • Page 49 Proline Promag L 400 [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1650 1082 – – 1284 1650 1800 1139 2210 2130 1379 1800 2000 1250 2428 2345 1569 2000 Dimensions in US units [in] [in] [in] [in] [in] [in] [in] 4.41...
  • Page 50 Proline Promag L 400 Dimensions in SI and US units Pressure rating [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] 2.05 3.98 115.5 4.55 4.25 2 ½ 2.68 4.76 131.5 5.18 4.65 3.15 5.16 154.5 6.08 5.31 4.09 6.14...
  • Page 51: Weight

    Proline Promag L 400 Pressure rating [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] 1 000 DIN, PN 10 39.2 – – 1 127 44.4 25.6 1 000 AS, PN 16 38.9 – – 1 131 44.5 26.0...
  • Page 52 Proline Promag L 400 Nominal EN (DIN) ASME, AWWA diameter [mm] [in] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] rating rating rating rating rating rating 1 400 – PN 6 PN 10 1114 PN 16...
  • Page 53 Proline Promag L 400 Nominal diameter ASME, AWWA [mm] [in] Pressure rating [lbs] Class 150 Class 150 – Class 150 Class 150 Class 150 Class 150 Class D Class D Class D Class D 1036 1 000 Class D 1294 –...
  • Page 54 Proline Promag L 400 Nominal EN (DIN) ASME, AWWA diameter [mm] [in] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] rating rating rating rating rating rating PN 6 – PN 10 – PN 16 Class 150 –...
  • Page 55 Proline Promag L 400 Nominal diameter EN (DIN) [mm] [in] Pressure rating [kg] PN 10 PN 10 Weight in US units Lap joint flange; fixed flange DN ≥ 350 (14") Nominal diameter ASME, AWWA [mm] [in] Pressure rating [lbs] Class 150 2 ½...
  • Page 56: Measuring Tube Specification

    Proline Promag L 400 Measuring tube specification Nominal diameter Pressure rating Measuring tube internal diameter EN (DIN) ASME AS 2129 Hard rubber Polyurethane PTFE AWWA AS 4087 [mm] [in] [mm] [in] [mm] [in] [mm] [in] PN 10/16 Class 150 –...
  • Page 57 Proline Promag L 400 Nominal diameter Pressure rating Measuring tube internal diameter EN (DIN) ASME AS 2129 Hard rubber Polyurethane PTFE AWWA AS 4087 [mm] [in] [mm] [in] [mm] [in] [mm] [in] – Class D – 29.3 29.4 – –...
  • Page 58: Materials

    Proline Promag L 400 Nominal diameter Pressure rating Measuring tube internal diameter EN (DIN) ASME AS 2129 Hard rubber Polyurethane PTFE AWWA AS 4087 [mm] [in] [mm] [in] [mm] [in] [mm] [in] 2 400 – PN 6 – – 2 394 95.8...
  • Page 59 Proline Promag L 400 Compact and remote versions and sensor connection housing Cable entry/cable gland Material Cable gland M20 × 1.5 Plastic Remote version: cable gland M20 × 1.5 • Sensor connection housing: Nickel-plated brass • Option CK "IP68, Type 6P, waterproof"...
  • Page 60: Fitted Electrodes

    Proline Promag L 400 Process connections EN 1092-1 (DIN 2501) • DN ≤ 300 (12"): 1.0038 (S235JRG2), 1.4301 (304), 1.4306 (304L), 1.4307 (304L) • DN ≥ 350 (14"): 1.0038 (S235JRG2), A105 ASME B16.5 • DN ≤ 300 (12"): A105, 316L •...
  • Page 61: Operability

    Proline Promag L 400 Operability Operating concept Operator-oriented menu structure for user-specific tasks • Commissioning • Operation • Diagnostics • Expert level Rapid and safe commissioning • Guided menus ("Make-it-run" wizards) for applications • Menu guidance with brief explanations of the individual parameter functions Reliable operation •...
  • Page 62: Remote Operation

    Proline Promag L 400 Remote operation Via HART protocol A0017124  28 Options for remote operation via HART protocol Control system (e.g. PLC) Field Communicator 475 Computer with operating tool (e.g. FieldCare, AMS Device Manager, SIMATIC PDM) Commubox FXA195 (USB)
  • Page 63: Certificates And Approvals

    Proline Promag L 400 A0016961 Ethernet network Automation system, e.g. "RSLogix" (Rockwell Automation) Workstation for measuring device operation: with Add-on Profile Level 3 for "RSLogix 5000" (Rockwell Automation) or with Electronic Data Sheet (EDS) Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with "FieldCare"...
  • Page 64: Ordering Information

    Proline Promag L 400 • CAN/CSA-C22.2 No. 61010-1-04 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 1 General Requirements • NAMUR NE 21 Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment. • NAMUR NE 32...
  • Page 65: Diagnostics Functions

    Proline Promag L 400 Diagnostics functions Package Description HistoROM extended Comprises extended functions concerning the event log and the activation of the function measured value memory. Event log: Memory volume is extended from 20 message entries (basic version) to up to 100 entries.
  • Page 66: Communication-Specific Accessories

    Proline Promag L 400 For the sensor Accessories Description Ground disks Are used to ground the fluid in lined measuring tubes to ensure proper measurement. For details, see Installation Instructions EA00070D Communication-specific Accessories Description accessories Commubox FXA195 For intrinsically safe HART communication with FieldCare via the USB interface.
  • Page 67: System Components

    Proline Promag L 400 Life cycle management for your plant W@M supports you with a wide range of software applications over the entire process: from planning and procurement, to the installation, commissioning and operation of the measuring devices. All the relevant device information, such as the device status, spare parts and device-specific documentation, is available for every device over the entire life cycle.
  • Page 68 www.addresses.endress.com...

Table of Contents