How To Fix - LG AMNH076LQL0 Service Manual

Multi type air conditioner
Hide thumbs Also See for AMNH076LQL0:
Table of Contents

Advertisement

How to fix

1. Room Type Indoor Unit Installation
The mounting wall should be strong and solid
enough to protect it from the vibration.
1) Mount the installation plate on the wall with
four Type "A" screws.
(If mounting the unit on the concrete wall, consid-
er using anchor bolts.)
• Always mount the Installation plate horizontally
by aligning the marking-off line by means of the
thread and a level.
2) Drill the piping hole with 70mm dia. holecore
drill.
• Line according to the arrows marked on lower
the left and the rght side of the Installation Plate.
The meeting point of the extended line is the
center of the hole.
• Drill the piping hole at either the right or the left
and the hole should be slightly slant to the out-
door side.
Type "A" screw
Weight
The lower left and the right side of
Installation Plate
C
Installation plate
Ø70mm
Left rear piping
CHASSIS
(Grade)
A
SQ(7/9k)
75
SR(9/12k)
0
ST(18/24k)
105
Installation plate
D
C
Ø70mm
Left rear piping
CHASSIS
(Grade)
A
S4
50
SE
65
S5
95
Installation
Installation Plate
marking-off line
Thread
A
Ø70mm
Right rear piping
Distance(mm)
B
C
D
12
80
12
40
20
40
0
210
0
B
A
Ø70mm
Right rear piping
Distance (mm)
B
C
D
105
59
105
110
85
110
122
235
122
Service Manual 35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents