Installation

How to Fix Installation Plate

The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
Installation Plate
Type "A" screw
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for pip-
ing connections must be done safely.
C
Installation plate
Ø70mm
Left rear piping
CHASSIS
(Grade)
A
SJ
90
SL, SK
45
SQ
75
SR
0
ST
105
Installation plate
Installation plate
C
E
Left rear piping
CHASSIS
(Grade)
A
SM
180
SN
180
14 Room Air Conditioner
A
Ø70mm
Right rear piping
Distance (mm)
B
C
20
80
40
80
12
80
40
20
0
210
A
Right rear piping
Ø70mm
Distance (mm)
B
C
D
115
-
115
115
195
115

Drill a Hole in the Wall

• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
Indoor
D
20
20
12
40
0
E
50
-
WALL
Outdoor