T e c h n o l o g y , L L C
•
Weekly – Drain water
1 . Turn off the engine and open the vent cap .
2 . Place a suitable eight ounce, plastic or metal container under the drain valve at the base of the Fuel Pro
and open the valve .
3 . Water will flow into the container . When fuel begins to flow out the drain, close the drain valve . Drain the
least amount of fuel as possible .
4 . Tighten the vent cap by hand until it clicks .
5 . Start the engine . Raise the RPM for one minute to purge the air from the system .
•
Every filter change
•
Change the cover and vent cap o-rings (included with the service filter kit) .
•
Every 12 months
•
Check all electrical connections for corrosion . Check all fuel fittings for leaks .
•
Seasonal Maintenance:
•
Extreme winter or salt corrosion environments may require lubrication of the collar threads with anti-seize
lubricant every 180 days .
DAVCO Technology, LLC
PREVENTIVE MAINTENANCE
P. O. Box 487
Saline, MI 48176
TECHNICAL MANUAL
Call 800-328-2611
11
FUEL PRO
®
www.davco.com
F1271 REV J
October 3, 2016 11:34 AM
382