Water In Fuel Sensor (Wif) Installation - Davco fuel pro 382 Technical Manual

Hide thumbs Also See for fuel pro 382:
Table of Contents

Advertisement

T e c h n o l o g y , L L C
1 . Remove the ½"-20 WIF plug in the bottom of the Fuel
Pro .
2 . Install the WIF Probe (See Service Parts Page for P/N)
into the bottom of the Fuel Pro . Torque to 20-24 in-lbs .
3 . Install the WIF wiring harness (P/N 102600) on WIF
Probe . The harness has the following connections:
black ground lead with a 3/8" diameter ring terminal
and a green WIF wire .
4 . Drill ½" hole in the instrument or control panel where
the WIF indicator light is to be located .
5 . Connect the black ground wire from the WIF indicator
light to a ground source . Attach additional black wire as
needed .
6 . Install the WIF indicator light by pressing firmly into the
drilled hole .
DAVCO Technology, LLC

WATER IN FUEL SENSOR (WIF) INSTALLATION

P. O. Box 487
Saline, MI 48176
TECHNICAL MANUAL
7 . Connect the black ground lead with a 3/8" diameter
loop end on the WIF wiring harness to the ground
source near the Fuel Pro (if applicable) .
8 . Connect the green signal wire on WIF wiring harness to
green signal wire on WIF indicator light . Use additional
green wire as needed .
9 . Locate 12VDC or 24VDC key controlled on power
source . Install a red wire from the power source to the
red wire on WIF indicator light . Add a 1 amp in-line fuse
(not included) .
Note: Use appropriate connectors to attach the wires . To
test the WIF indicator light, pour water into the body of the
Fuel Pro until it covers the WIF probe . The WIF indicator
light should illuminate .
Call 800-328-2611
10
FUEL PRO
®
www.davco.com
F1271 REV J
October 3, 2016 11:34 AM
382