Alignment Of Pll And Carrier Oscillator; Test Equipment Required; Pll And Carrier Oscillator Test Equipment Setup - Realistic TRC-449 Service Manual

Cb
Hide thumbs Also See for TRC-449:
Table of Contents

Advertisement

ALIGNMENT OF PLL AND CARRIER OSCILLATOR
1. Test equipment required:
a. Oscilloscope (DC - 50 MHz)
b. Frequency counter (0 - 30 MHz)
c. DC Power Supply
(13.8V 100 mA)
d. DC Voltmeter (1 OV Maximum 100Kohm/V)
e. 50 ohm Load
2. Alignment procedure: (See page 8)
Connect Test Equipment as shown below.
STEP
PRESET TO
CONNECTIONS
ADJUSTMENT
REMARKS
1
RX, AM, CH19
TP6
L24
Adjust for max. output.
Clarifier: in center position
2
RX, AM, CH 1
TP7
L17
Adjust for 2 V reading on Voltmeter.
Clarifier: in center position
3
Same as Step 1
TP8
L16
Adjust for max. output.
4
Same as Step 1
TP8
CT6
Adjust to obtain 34.985 MHz ±20 Hz
on frequency Counter.
5
RX, USB, CH19
TP8
CT4
Adjust to obtain 34.9875 MHz ±20 Hz
Clarifier, in center position
on frequency Counter.
6
RX, LSB, CH19
TP8
CT5
Adjust to obtain 34.9825 MHz ±20 Hz
Clarifier: in center position
on frequency Counter.
7
TX, LSB, CH19
TP8
VR9
Adjust to obtain 34.9825 MHz ±20 Hz
on frequency Counter.
S
Same as Step 7
TP9
CT3
Adjust to obtain 7.7975 MHz ±5 Hz
on frequency Counter.
9
TX,USB,CH19
TP9
CT2
Adjust to obtain 7.8025 MHz ±5 Hz
on frequency Counter
.
PLL AND CARRIER OSCILLATOR TEST EQUIPMENT SETUP
EJE]
DC Power Supply
13.8V
-9-
Frequency Counter
o
Oscilloscope
DC Voltmeter