controlled in line with cooling auto fan with temperature set to be 24° C.
The others models:
8.3.6.1 Under this mode, four-way valve, compressor and outdoor fan are shut down,
indoor fan keeps on.
8.3.6.2 High/Med/Low/Auto fan can be switched over through manual control.
8.3.6.3 Under auto mode, the indoor fan is set to be Med.

8.4 Other functions

8.4.1 LCD display
Mode, Set temperature, fan speed, time, timer, etc.
8.4.2 Timer
The machine should be provided with max. Interval of 24h.

9. Trouble shooting

9.1 Self-diagnosis

MFE-60ARN1-RB4W (2T0043800036):
Codes
Contents
P4
Protection of temperature of indoor evaporator
P5
Protection of temperature of outdoor condenser
P7
Compressor discharge temperature protection
P9
Protection of anti-cold wind
P10
Low pressure protection
P11
High pressure protection
P12
Current overload protection
E1
Open- or short-circuit of T1 temperature sensor
E2
Open- or short-circuit of T2 temperature sensor
E3
Open- or short-circuit of T3 temperature sensor
E4
Open- or short-circuit of T4 temperature sensor
E5
Communication malfunction between indoor unit and outdoor unit
E10
Low pressure failure of compressor
E13
Lack of phase
E14
Default phase of compressor
E15
Indoor fan speed is out of control
EC
Refrigerant Leakage Detection
40