Red Arrow SMAS-P Installation Instructions Manual

Red Arrow SMAS-P Installation Instructions Manual

Photoelectric smoke alarm

Advertisement

Photoelectric Smoke
Alarm
Installation
Instructions P .1.
For models: SMAS-P
This installation must be carried out by an electrician.
Please read these instructions carefully before installation.
Leave a copy for the user/maintenance engineer for future reference.

Main Features

AC/DC operated Photoelectric type Smoke Alarm
Photoelectric Sensor
Non-radioactive technology
High and stable sensitivity
Operated with 220-240V AC 50Hz
and 9V DC Battery back-up
Compact size: 110mm diameter
Quick fix mounting bracket and simple
AC connector for easy installation
Fitting and battery tamper-resist
feature
Inter-connectable up to 40 units
Self-test button
2 Colour LED indicator (Alarm and
AC power indicator)
Extra loud alarm sound over 85dB
Low-battery and battery missing warning indicator
Auto-reset when smoke clears

Specification

Model: SMAS-P
Operating Temperature: 5°C to 45°C.
Electrical Rating: 220-240V AC 50Hz
and 9V DC Battery back-up
Battery Back-Life: In the event of a break in the mains
supply the battery will give detector operation for 1 year
minimum
Standby Current (9V Battery): 15uA max
Alarm Current (9V Battery): 30mA max
Horn Output: 85 Decibles at 3m (10 feet)
Humidity Rating: 10%-90%
Interconnect Quantities: 40 Smoke detectors and / or heat
detectors over 150m maximum

IMPORTANT SAFETY INFORMATION

1.
This smoke alarm requires constant 220-240V AC 50Hz
mains power supply to operate properly. Backup 9V DC
battery will offer additional protection in the event of power
failure. This smoke alarm WILL NOT work if AC power is
not connected ir has failed or been interrupted for any
reason. AND if the backup battery is removed, drained or
improperly connected, the alarm will not work during a
power failure. DO NOT use any other kind of battery except
as specified.
2.
The Push-to-test button accurately tests all smoke alarm
functions. Do not use any other test method. Test smoke
alarm weekly to ensure proper operation.
3.
DO NOT cut off AC power supply or remove or disconnect
backup battery to quiet unwanted alarms. This will remove
your protection. Open windows or fan the air around smoke
alarm to silence it.
4.
Observe and follow all local and national electrical and
building codes for installation.
5.
This smoke alarm is designed to be used inside a single room
only. In multi-room buildings, each individual living unit
should have its own smoke alarm. Do not install in non-
residential buildings. And this smoke alarm is not a
substitute for a complete alarm system.
6.
Smoke may not reach the smoke alarm for many reasons.
For example, if a fire starts in a remote part of the home,
on another level, in a chimney, wall, roof, or the other side
of a closed door, smoke may not reach the smoke alarm
in time to alert household members. A smoke alarm will not
promptly detect a fire except in the area or room in which
it is installed.
7.
Smoke alarms may not alert every household member every
time. The alarm horn is loud in order to alert individuals
to a potential danger. However, there may be limiting
circumtances where a household member may not hear the
alarm (i.e. outdoor or indoor noise, sound sleepers, drug or
alcohol usage, the hard of hearing, etc.). If you suspect that

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMAS-P and is the answer not in the manual?

Questions and answers

Summary of Contents for Red Arrow SMAS-P

  • Page 1: Main Features

    Photoelectric Smoke Alarm Installation Instructions P .1. For models: SMAS-P This installation must be carried out by an electrician. Please read these instructions carefully before installation. Leave a copy for the user/maintenance engineer for future reference. • Humidity Rating: 10%-90% Main Features •...
  • Page 2 this smoke alarm may not alert a household member, install and maintain specialty smoke alarms. Household member must hear the alarm’s warning sound and quickly respond to it to reduce the risk of damage, injury, or death that may result from fire. If a household member is hard of hearing, install special smoke alarms with lights or vibrating devices to alert occupants.
  • Page 3: How To Install This Smoke Alarm

    Near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, hot water heaters). Use specialised smoke alarm with unwanted alarm control for these areas. In areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 10 feet away from these areas.
  • Page 4: Battery Replacement

    Position smoke alarm to mounting plate and turn clockwise to lock into place. To engage tamper-resist feature, insert pin into notch on edge of smoke alarm after alarm is properly positioned in base. NOTE: Smoke alarm will not mount to plate if battery is not installed. Turn on power at main fuse box or circuit breaker.
  • Page 5: What To Do In Case Of Fire

    Replace the battery at least once a year or immediately when the low battery signal sounds once a minute, even though the smoke alarm is receiving AC power. Batteries should be replaced regularly as neccessary. WARNING: Do not use any other type of battery, except specified in this manual. Do not use rechargeable batteries. CAUTION: Explosion will happen if battery is incorrectly replaced.
  • Page 6: Troubleshooting

    Mega tested. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. We do not accept responsibility for any installation costs associated with the replacement of this product. We reserve the right to alter specifications without prior notice. Red Arrow Trading T: 0800 195 0006 F: 0870 043 3946 E: sales@redarrowtrading.com...