General Characteristics Page; Physical Data; Electrical Data; Operating Limits - Lennox COMPACTAIR CSC Installation, Operating And Maintenance

Vertical packaged air conditioner outdoor unit
Table of Contents

Advertisement

1.- GENERAL CHARACTERISTICS

1.1.- PHYSICAL DATA

C
S
Unit
COMPACTAIR
S: Outdoor unit Split
D: Outdoor unit Multi-split
UNIT MODELS
Compressor
CSC/CDC Cooling only unit
Net Weight
(Kg)
CSH/CDH Heat pump unit
Air flow
Refrigerant charge
(*) The units are supplied with nitrogen gas; this must be
removed and the unit charged with refrigerant R-410A,
depending on unit model.

1.2.- ELECTRICAL DATA

ELECTRICAL CONSUMPTION FOR STANDARD UNITS
UNIT MODELS
Maximum absorbed power
Compressor
Fan
Total power
Maximum current
Compressor
Fan
Total current
Start up current
Voltage
1.3.- OPERATING LIMITS (For installation with CIC-CIH units)
OPERATING LIMITS FOR (COOLING ONLY) UNITS
COOLING CYCLE
OPERATION
(*) With option kit low temperature 0ºC.
OPERATING LIMITS FOR (HEATING PUMP) UNITS
INDOOR TEMPERATURE
COOLING CYCLE
OPERATION
OUTDOOR TEMPERATURE
INDOOR TEMPERATURE
HEATING CYCLE
OPERATION
OUTDOOR TEMPERATURE
DB: Dry bulb temperature.
C
020
C: Cooling only
H: Heat pump
Approximate cooling
capacity in kW
CSC/CDC: Cooling only unit R-410A.
CSH/CDH: Heat pump unit R-410A.
CSC
CSH
020S
(Nr. / Type)
1/Scroll
(Kg.)
257
(Kg.)
262
(m
3
/h)
7600
CSC
CSH
020S
(kW)
8.25
1.45
9.7
(A)
15
2.59
17.59
(A)
88.4
V/f (50Hz)
INDOOR TEMPERATURE
OUTDOOR TEMPERATURE
S
N
S: One Circuit
D: Two Circuits
No heat
CSC
CSC
CSC
CSH
CSH
CSH
025S
030S
035S
1/Scroll
1/Scroll
1/Scroll
290
297
352
295
302
357
8500
10000
12000
(see page 23 to calculate refrigerant charge for model CSC/
CDC and CSH/DCH units to work with indoor units CIC/CIH).
R-410A factory refrigerant precharge kit is available as an
option.
CSC
CSC
CSC
CSH
CSH
CSH
025S
030S
035S
10.1
11.8
15.5
1.89
2.69
2.69
11.99
14.49
18.19
21
22
25.6
3.45
4.8
4.8
24.45
26.8
30.4
97.8
105.1
139.1
MAXIMUM TEMPERATURES
32ºC DB / 23ºC WB
45ºC (020-025-030-045-055)
47ºC (035-040-070-085-100)
(**) With option kit low temperature -15ºC.
MAXIMUM TEMPERATURES
32ºC DB / 23ºC WB
45ºC (020-025-030-045-055)
47ºC (035-040-070-085-100)
27ºC DB
27ºC
(With 20ºC outdoor temperature)
WB: Wet bulb temperature
(*) With option kit low temperature -15ºC.
4
M
Type of refrigerant
M: R-410A
Number
of revision
CSC
CSC
CSC/CDC
CSC/CDC
CSH
CSH
CSH/CDH
CSH/CDH
040S
045D
055D
1/Scroll
2/Scroll
2/Scroll
365
443
524
370
448
529
11700
14000
20000
NITROGEN(*)
CSC
CSC
CSC/CDC
CSC/CDC
CSH
CSH
CSH/CDH
CSH/CDH
040S
045D
055D
16.9
20.2
23.5
2.69
3.63
5.38
19.59
23.83
28.98
31
42
44
4.8
6.48
9.6
35.8
48.48
53.6
131.9/
152.7
121.8
210.2
3~400V 50Hz
MINIMUM TEMPERATURES
21ºC DB / 15ºC WB
+10ºC STANDARD UNIT
0ºC (*)
-15ºC (**)
MINIMUM TEMPERATURES
21ºC DB / 15ºC WB
0ºC UNIDAD ESTÁNDAR
15ºC DB
(With 20ºC indoor temperature)
3
M
M: 400V/3/50
CSC/CDC
CSC
CSH/CDH
CSH
070D
085D
100D
2/Scroll
2/Scroll
2/Scroll
549
581
865
554
586
870
21000
22000
15500+11700
CSC/CDC
CSC
CSH/CDH
CSH
070D
085D
100D
31
33.8
42.5
5.38
7.26
7.75
36.38
41.06
50.25
51.2
62
77.6
9.6
12.96
13.4
60.8
74.96
91
169.5/
191.9/
207.9
278.2
308.8
-15ºC (*)
-12ºC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compactair cdcCompactair cdhCompactair csh

Table of Contents