MIS-4220 / MIS-4220R / MIS-4230
4. How to Connect Cables

4.1. Connection of one set MPDP

PC & DVi Connection
y
MPDP and PC should be connected; a Com Port in a PC and RS-232C IN port in a
MPDP is connected with supplied RS-232C cable.
y
MPDP On/Off or Screen adjustment can be controlled by MSCS (Multi-Screen Control
System).
y
ID setting on the backside of MPDP must be identical with the ID setting in MSCS to
control MPDP with a PC.
y
If you do not have Com Port, you need to use an USB converter for RS-232. Depending
on manufacturers or models, converters may cause malfunction.
PC (MSCS) to control MPDP
Downloaded From TV-Manual.com Manuals
RS-232C (Maximum 15m)
PC
PC- analog connection (Maximum 5m)
DVI connection (Maximum 5m)
※ If you need longer connection, please use
DVI boosters or DVI fiber-optic cable.
16
Infinitely Expandable
RS-232C
VIDEO
IN
IN
OUT
S-VIDEO
OUT
IN
OUT
COMPONENT
Pr
Pb
Y
OUT
IN
ID SELECT
M-ON
FAN
M-STB
S-ON
DVI-D
PC
OUT
OUT
IN
IN
17
[PDP ID 1]
y
ID switch must be set as ID 1
for one set use.