The system detects an incoming call.
Does the Setup message
contain a called number?
Is there a Called Party
Number in the DID table
Normal DID routing occurs.
VoIP PCB Setup Examples
The following are examples of connection and setup. It is recommended, however, to consult with your MIS network administrator
regarding IP address settings before using the VoIPU.
Program 0319:
Operating Mode
Program 0153:1
IP Address
Subnet Mask
Router (Default Gateway)
Program 0153:2
Gatekeeper connection mode
Gatekeeper Address
RAS Port
Router IP Address
Subnet Mask
Global IP Address
DID Incoming Routing with VoIP
Start
Yes
(Program 1805)?
Yes
No
Should the call follow
DID Error Routing
No
(Program 1810)?
Yes
The system follows Program
1809 intercept ring group
routing.
Stop
VoIPU Setup
1 - Manual Setting
Router Setup
Automatically assigned
No
Warning tone is heard.
1 - NT mode
128.10.0.1
255.255.0.0
128.10.0.2
128.10.0.3
1719
128.10.0.2
255.255.0.0
Page 7