ADJUSTMENTS
2.
Adjustment of Timing Belt Tension
(1)
Remove the upper case unit according to the procedures described in chapter 4.
Loosen screw [1].
(2)
(3)
Move the carriage [2] once from left to right, then return it to the left.
(4)
Set the tension gauge [3] to the position indicated in Fig. 3-5 below.
(5)
Using a regular screwdriver, move tension lever [4] to the right until it matches the minimum tension setting
(23.0 if LC-4511; 28.0 if LC-4521).
Tighten screw [1].
(6)
(7)
Confirm that the setting is correct.
Remove tension gauge [3]. Move the carriage [2] all the way to the right and then back to the left, and check the
(8)
setting once again.
Fig. 3-5 Positioning the carriage unit
Fig. 3-4 Gap measurement
Gauge lever
position
0~10mm
Fig. 3-6 Measuring tension
– 34 –
Platen
Timing belt